To compare surgically induced astigmatism in SICS using two different incision sites – “superior vs. temporal”

Journal Title: Indian Journal of Clinical and Experimental Ophthalmology - Year 2017, Vol 3, Issue 4

Abstract

Cataract is one of the most important curable causes of blindness in India. Nowadays although the ‘cataract surgery of choice’ is phacoemulsification; manual small incision cataract surgery (SICS) has emerged as an alternative technique owing to its being cost-effective and having all advantages of a self-sealing sutureless incision but with the disadvantage of having higher postoperative astigmatism. The aim of our study was to compare the surgical outcome using two different incision sites – “superior and temporal” in terms of surgically induced astigmatism. After taking Informed consent all the patients were divided randomly into two groups. Group S received Superior incision and group T Temporal incision. All surgeries were performed under peribulbar anesthesia using an incision size of 6 – 6.5 mm. The incision architecture was kept same in both the groups. Postopratively patients were examined on days 1, 7, 30, 45 and 90. Keratometry with Uncorrected and Best corrected visual acuity was recorded on subsequent visits. The surgically induced astigmatism (SIA) was calculated by Vector method. When SIA was compared between the two groups, both in magnitude as well as axis, the change was found to be lower in temporal group as compared to superior group S. It was statistically significant (p=0.004). We therefore conclude that though both the groups had good postoperative visual acuity patients of group S had more postoperative and surgically induced astigmatism and therefore greater dependence on spectacles as compared to group T and this was found to be statistically significant.

Authors and Affiliations

Rohit Saxena, Poonam Kishore, Sandeep Saxena

Keywords

Related Articles

Visual outcome of hydrophilic and hydrophobic foldable posterior chamber intraocular lenses in cataract surgery

Introduction: As there is no pharmacological treatment for cataract, the standard treatment is surgical removal of the opacified lens and implantation of an artificial intraocular lens (IOL). The standard method of catar...

Study of normative data of ephios handheld electroretinogram

Objective: 1) To analyse normative data from Ephios Handheld Electroretinogram. 2) To compare the obtained normative data with that of existing data of both handheld and table top Electroretinogram. Method...

Clinical profile of childhood blindness in a tertiary eye care centre in central India

Objectives To determine institution based incidence of childhood blindness and to study its clinical profileType of Study An observational retrospective institution based studyMaterials and Methods This study was conduct...

The prospective study of clinico-etiological analysis on patients of papilloedema

Background: As the etiologies of papilloedema are important from prognostic point of view, early recognition of its cause & prompt treatment is required for better visual outcome. Objective: To study the etiology of the...

Qualitative analysis of refractive errors in school children

PurposeTo study the refractive errors and its implication on the quality of life among the children in the semi urban populationMaterials and Methods This prospective crosssectional study was conducted among the 500 chil...

Download PDF file
  • EP ID EP302538
  • DOI 10.18231/2395-1451.2017.0114
  • Views 64
  • Downloads 0

How To Cite

Rohit Saxena, Poonam Kishore, Sandeep Saxena (2017). To compare surgically induced astigmatism in SICS using two different incision sites – “superior vs. temporal”. Indian Journal of Clinical and Experimental Ophthalmology, 3(4), 470-475. https://europub.co.uk/articles/-A-302538