To compare the Gonioscopic changes in the angle after conventional ECCE with PC IOL implantation and Small Incision Cataract Surgery with PCIOL

Journal Title: Indian Journal of Clinical and Experimental Ophthalmology - Year 2017, Vol 3, Issue 3

Abstract

Introduction: To observe and compare the Gonioscopic changes in the angle after · Conventional ECCE with PC IOL implantation · Manual Small incision Cataract Surgery with PCIOL implantation An attempt has been made to note the progression of these changes and the possible effects of these changes over the Intra Ocular Pressure and Postoperative Visual acuity. Materials and Methods: This clinical study was undertaken in 100 Eyes- 50 ECCE; 50 SICS consisting of 57 Males and 43 Females aged between 40 - 80yrs who were admitted and operated for Cataract at Saveetha Medical college Hospital, Thandalam. After Securing the inform consent, total number of 100 patients were enrolled for the study. Study was statistically analysed by Chi-squared Test. The filtration angle of each Eye was examined with a Goldmann two mirror Gonio Lens Pre Operative and Post Operatively in a prospective manner. Post Operative Gonioscopic examination was performed between 6 weeks and 3rd Post Operative month to observe any changes. Results: Posterior chamber IOL implantation was undertaken in total 100eyes among which 57 Males and 43 Females majority aged between 50 – 60 years. 50patients underwent ECCE with PC IOL implantation. 50 patients underwent Small Incision Cataract Surgery with PCIOL Implantation. PAS formation was observed in 28 eyes of 50 cases, which underwent conventional ECCE with PC IOL implantation. No PAS was seen in eyes that underwent SICS, Superior angle PAS noted in 23 eyes. Inferior angle PAS in 5 eyes. 20 eyes showed PAS overlying the Haptics of PC IOL. Which accounts to 71.4%. Most of the lens Haptics PAS were observed early in the Post operative period (3 Months) and remain stable in size. The Scheie’s method of grading TM pigmentation was followed. Large numbers represent increasing amount of pigmentation. Conclusion: Conventional Extra Capsular Cataract Extraction with PC IOL implantation significantly and permanently alters the Gonio Anatomy of the Eye when compared to Small Incision Cataract Surgery. (P < 0.001). Decrease in the incision size, anterior entry into the cornea with a self-sealing Scleral tunnel incision and a Corneal lip prevents the formation of PAS. In the Bag fixation of IOL reduces Iris chafing related pigment dispersion into the AC and lowers the incidence of changes in the angle. (P <0.001). Continuous Curvilinear Capsulorhexis (CCC) is important for proper capsular bag fixation of the IOL. (P <0.001).

Authors and Affiliations

Keywords

Related Articles

Comparison of post operative astigmatism from superiotemporal vs temporal incision in small incision cataract surgery

Introduction: Cataract surgery has become one of the most common and successful procedures in ophthalmology. In addition to improving visual acuity (VA), one of the goals of modern cataract surgery is to reduce pre-exist...

Glaucoma and diabetes: A review

Glaucoma is ranked second amongst the causes of irreversible blindness worldwide Diabetes mellitus DM is a global public health concern with numerous microvascular complications There is increasing evidence to suggest th...

Hospital prevalence and major causes of low vision in a tertiary care centre in South India: A Hospital record based study

Aims To determine the hospital prevalence as well as the low vision causes among patients coming to a tertiary care centreSettings and Design Retrospective study was conducted by review of files of patients who presented...

Visual function and quality of life amongst patients with cataract attending Ophthalmology camps in a coastal district in Southern India

Introduction Aim of the study was to measure the visual function and quality of life amongst cataract patients attending campsMethodology A cross sectional study was conducted among patients attending Ophthalmology camp...

Statistical Errors in Ophthalmic Research

“Biomedical statistics is essential part of any scientific study; a review of the current scientific literature indicates that statistical analysis is an area that frequently needs improvement. To address this, we put fo...

Download PDF file
  • EP ID EP300867
  • DOI 10.18231/2395-1451.2017.0093
  • Views 93
  • Downloads 0

How To Cite

(2017). To compare the Gonioscopic changes in the angle after conventional ECCE with PC IOL implantation and Small Incision Cataract Surgery with PCIOL. Indian Journal of Clinical and Experimental Ophthalmology, 3(3), 380-383. https://europub.co.uk/articles/-A-300867