Traction Enhancing Products Affect Maximum Torque at the Shoe-Floor Interface: A Potential Increased Risk of ACL Injury

Journal Title: American Journal of Engineering and Applied Sciences - Year 2016, Vol 9, Issue 4

Abstract

Abstract The knee is one of the most frequently injured joints in the body, between 100 000 and 400 000 Anterior Cruciate Ligament (ACL) injuries occur in the United States each year. This investigation explores the impact of wipe- or spray-on sneaker products used to increase traction between shoes and hardwood courts on the loading of the ACL. Specifically, the maximum torque achieved prior to the sneaker slipping on the court surface is measured using a servo-hydraulic bi-axial load frame. A prosthetic foot fitted into a sneaker was fixed to the load cell and a piece of hardwood court was fixed to the actuator of the load frame. Axial loads were applied to simulate an athlete's body weight and torques were applied to simulate an athlete pivoting on a hardwood surface. The maximum torque achieved prior to the sneaker slipping on the hardwood surface was measured. The investigation finds that the application of the wipe- or spray-on sneaker products increases the maximum torque achieved prior to the sneaker slipping by 164%. This increase in torque exceeds prior published levels of torque that resulted in ACL failure in a cadaveric model. Copyright © 2016 Morse A., M. M. Mansfield, R. M. Alley, H. A. Kerr and R. B. Bucinell. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Authors and Affiliations

A. Morse, M. M. Mansfield, R. M. Alley, H. A. Kerr, Ronald B. Bucinell

Keywords

Related Articles

Control of Bubble Formation at the Optical Fiber Tip by Analyzing Ultrasound Acoustic Waves

Abstract The problems of controlling the processes of generation of acoustic waves and microbubbles at the optical fiber tip of moderate-power surgical lasers with wavelengths of 1.9 µm and 0.97 µm using active and pass...

Integration of Human Factor in Design Ergonomics: Example of a High Speed Train Cabin Design

Abstract The development of new technologies and technical progress has accelerated man/machine substitution. Work is disappearing in its human form. This technical progress has not avoided certain catastrophes occurrin...

Industrial Robot Fault Detection Based on Statistical Control Chart

Industrial Robot Fault Detection Based on Statistical Control Chart Alaa Abdulhady Jaber and Robert Bicker DOI : 10.3844/ajeassp.2016.251.263 American Journal of Engineering and Applied Sciences Volume 9, Issue 2 Pag...

Updating Italian Design Guide CNR DT-205/2007 in View of Recent Research Findings: Requirements for Pultruded FRP Profiles

Abstract A discussion on some design rules for pultruded fiber-reinforced plastic (PFRP) profiles reported by guideline CNR DT-205/2007 from National Research Council of Italy is presented in the paper. At eight years a...

Mitochondria are Naturally Micro Robots - A review

Abstract The mitochondrion is a natural robot (cell) with a length of about one micron. Between organisms (plant, animal or human) with its organs and the atomic and molecular components are positioned based cells, whic...

Download PDF file
  • EP ID EP202265
  • DOI 10.3844/ajeassp.2016.889.893
  • Views 94
  • Downloads 0

How To Cite

A. Morse, M. M. Mansfield, R. M. Alley, H. A. Kerr, Ronald B. Bucinell (2016). Traction Enhancing Products Affect Maximum Torque at the Shoe-Floor Interface: A Potential Increased Risk of ACL Injury. American Journal of Engineering and Applied Sciences, 9(4), 889-893. https://europub.co.uk/articles/-A-202265