Transcervical Migration of an Essure® Coil

Journal Title: Hospital Practices and Research - Year 2019, Vol 4, Issue 2

Abstract

Introduction: Essure® device malposition is a rare, but clinically significant complication, for which management is idiosyncratic. This case report describes an unusual example of Essure® migration in order to clarify reasonable management options. Case Presentation: A 50-year old G4P2022 underwent hysteroscopic sterilization using the Essure® device. Insertion was complicated by fragmentation of both coils. Two years later, one of the coils was incidentally discovered protruding through the cervical os. The visible portion was clipped when attempts to remove the entire coil were unsuccessful. Conclusion: Difficult placement increases the risk of Essure® malposition. In asymptomatic patients, conservative management with removal of only a portion of the device is a rational approach.

Authors and Affiliations

Keywords

Related Articles

The Feasibility of Deploying Business Process Management in Hospitals in Iran

Background: Business process management systems (BPM) can automate all processes in an organization. These systems provide the possibility of identifying, modeling, deploying, implementing, function managing, integrating...

The Future of Healthcare Facilities: How Technology and Medical Advances May Shape Hospitals of the Future

In this review article, we aim to depict how healthcare facilities may look in the near future from an architectural design point of view. For this purpose, we review newly introduced technology and medical advances in t...

Using Linear Regression to Identify Critical Demographic Variables Affecting Patient Safety Culture From Viewpoints of Physicians and Nurses

Background: The issues of patient safety and healthcare quality have become increasingly important around the world since the 1990s. Many hospitals manage to reduce the number of adverse events (AEs) that can threaten pa...

Seroprevalence of Hepatitis B and C Infections in Mokolo District Hospital, Northern Cameroon: The Value of a Screening Campaign

Background: Infections due to the hepatitis B (HBV) and hepatitis C (HCV) viruses constitute a global public health problem. Although screening of these infections remains a pivotal tool for timely detection and manageme...

Effects of Patient Education Program on the Quality of Nursing Care and Inpatient Satisfaction in Surgical Wards of Selected Hospitals in Isfahan, Iran

Background: The implementation of patient education within a hospital is a difficult task that plays a key role in improving and controlling diseases and providing quality healthcare services. Objective: The current stud...

Download PDF file
  • EP ID EP603599
  • DOI 10.15171/hpr.2019.13
  • Views 105
  • Downloads 0

How To Cite

(2019). Transcervical Migration of an Essure® Coil. Hospital Practices and Research, 4(2), 71-74. https://europub.co.uk/articles/-A-603599