Transfer function and Impulse Response Simulation of Power Line Channel
Journal Title: UNKNOWN - Year 2013, Vol 2, Issue 8
Abstract
Due to increasing complexity, space and cost of communication network, the Electric Power Network has been considered a great option for the solution of all problems. Power line communications (PLC) term stands for the technologies for the data communication over the electrical power supply network. Existing power system is not designed for having data transfer. In this paper we have developed a simulation model of power-line for low voltage distribution network in home. Impulse response of the channel is generated in order to characterize the behavior of power line channel for high speed data communication purpose. To represent Multi-branch network mathematically, ABCD matrix parameters are used. Load mismatching is experimented on three parameters multiple loading, multi-branch and different cable length and analysis is presented of its effect on impulse response. All the simulation work has been done using MATLAB.
Cochlear Implant in Deaf and Blind Patient
Patients with multiple sensory deficits such as hearing loss and visual impairment (VI) represent a unique problem. The most common syndrome of deaf and blind- Usher syndrome comprises of retinitis pigmentosa and progres...
Success Factors and Change Management in Malaysian Institutions of Higher Learning (IHL)
More and more researchers and academic practitioners in Malaysia turn their interest into learning how the Institutions of Higher Learning (IHL) accommodate their success factors in change management. IHL, administered u...
Enhancing the Character Segmentation Accuracy of Bangla OCR using BPNN
Bangla is one of the most popular scripts in the world, the second most popular language in the Indian subcontinent. About 200 million people of eastern India and Bangladesh use this language, making it fourth most popul...
Assessment of Dry Mass Loss of Stored Cereals Due to Increment of Stored Temperature in Line with Global Warming
To monitor respiratory climacteric behavior of grains due to global warming, a study was conducted using paddy, green gram, corn and cowpea at initial moisture contents of 10.9%, 8.6%, 8.9% and 10.6% respectively. These...
A Case Report of Posner Schlossman Syndrome
A 43 year old male presented to the emergency room of Assam Medical College & Hospital, Dibrugarh, with the chief complains of vision of right eye with redness, fogginess of vision, pain and vomiting. There was corneal...