Abstract

Objective: To achieve union at nonunion site with correction of limb length discrepancy and correction of deformity with early function and mobilization. Methods: It is prospective study of treatment of aseptic nonunion of shaft tibia. Total 35 patients of tibial nonunion were studied. All relevant pre and perioperative information and complications were recorded. Also assessment of functional outcome was made. Results: In present series 32 out of 35 cases has united, about 91% success rate. The average duration of nonunion was about 14.5 months, average union time (fixator removal) is about 6.2 months. Two of our patient were showing poor tolerance to ilizarov external fixator changed to other modality. Conclusion: Ilizarov technique is very helpful in treating nonunion of long bones and has advantage of early wt. Bearing, movements of nearby joints encouraged which reduces edema and joint stiffness.

Authors and Affiliations

V R Rokade, Pankaj Lawate, Anant Chowgule

Keywords

Related Articles

A study of surgical management of tibial condylar fractures

Background: Tremendous advance in mechanization and fastness of travel have been accompanied by steep increase in number and severity of fractures and those of tibial condyles are no exception. Knee being one of the majo...

Valgus intertrochanteric osteotomy along with use of dynamic hip screw for fixation of neck femur fractures: An experimental study from Maharashtra

Background: Various factors affecting the fracture neck femur outcome and the controversies regarding its management has always been a challenge. With advent of the automobile age and the rapid urbanization, road traffic...

Study on the proximal femoral nail fixation for unstable trochanteric fracture

To assess the clinical, radiological and functional outcome of unstable trochanteric fracture when treated with PFN. Totally 20 cases of unstable trochanteric fractures selected for this prospective study at Department o...

A randomized control trial of clinical outcome of open fractures of tibia with titanium plates vs stainless steel plate at a tertiary care center

Background: Open fractures are often associated with high energy injuries. Plating method of fractures stabilization help in early recovery. Titanium plates though costly have shown more safe than stainless steel plates...

Failed hip surgeries managed with replacement arthroplasty: A retrospective study of 25 cases

Background: Hip fractures account to succumb devastating lifestyle and early mortality in older comorbid patients. Fractures of the hip region need anatomical fixation and osteosynthesis. But implant failures are associa...