Tympanic Membrane or Temporal Artery Thermometry: Which is More Reliable for Children?
Journal Title: International Journal of Science and Research (IJSR) - Year 2015, Vol 4, Issue 1
Abstract
Abstract : Background: Evaluation of body temperature is one of the oldest known diagnostic methods and is still an important sign of health and disease, both in everyday life and in medical care. Objective: To assess and compare the accuracy of temperature measured by tympanic membrane thermometry and temporal artery thermometry with reference to the axillary thermometry among children. Temperature of 300 children between the age group of 2-6 years was assessed and compared by using digital axillary thermometer(Omron MC-246), infra red tympanic membrane thermometry (infinity check FDIR-V1) and infra red temporal artery thermometry (infinity check FDIR-V1). Results: More than half (53%) of children were in age group of 4-6 years and majority (69%) of the children were male . The range of temperature measured by tympanic membrane thermometry (92.6-99.5) was more close to the range of temperature measured by axillary thermometry(92-100.2) as compared to the temporal artery thermometry (92.6-99.5). The calculated F value by using ANNOVA showed that (222.2) is greater than tabulated F value (2.99) at 0.05 level of significance. Conclusion: Axillary thermometry cannot be replaced by tympanic membrane thermometry in paediatric population where a quick, comfortable and more accurate thermometry is required.
Survey on Implementation of Radiological Image Retrieval in CBIR System
This article gives an overview of the retrieval of Medical images from the Health Care Database. This working model aimed on the concept of content-based image retrieval (CBIR) system. The main goal of this model is to r...
Oxidative/Antioxidant Status of Different Muscles of Fresh Pork Meat
The main aim of the work is to investigate and compare oxidative/antioxidant status in different muscles (M. Subscapularis, M. Longissimus and M. Gluteobiceps) of fresh pork meat through some Real time biomarkers of radi...
Performance Analysis of Shunt Active Power Filter with Different Switching Signal Generation Techniques
The performance of shunt active power filter (SAPF) is compared for steady state load condition. The SAPF is used for harmonic compensation of single phase ac/dc converter feeding a nonlinear load. The process involves a...
Role of Rush Nail in Fracture Forearm Bones with or Without Bone Graft
"Background: Rush nail is a very handy, low cost easily available implant. In the present study, we have tried to find out its applicability in fracture of both bones with ORIF with or without Bone graft. The objectives...
Factors Affecting E-Procurement Adoption in Minimizing Risks in the Supply Chain: A Survey of State Corporations in Kenya
This paper examines the optimization of purchasing through the use of Internet based systems (electronic Procurement). The focus of this paper is the impact of these systems on the supply chain structure and how they are...