Use direct volume magnetostatic waves for convolver construction

Abstract

It is shown that the use of direct volume magnetostatic waves (FVMSW) in epitaxial ferrite film can be the basis for convolver construction. A theoretical analysis confirmed that the output signal corresponds to the double compressed in time (because of counter motion waves that carry signals) convolution function at the input signals. Defined expression for calculating signal of convolution, which takes into account the frequency characteristics of a magnetized film as waveguide structure, the sizes of the film and the antenna in form a rectangular loop, the induced voltage which corresponds to the signal convolution. For FVMSW limit signals, beyond which there is an unstable nonlinear phenomena associated with parametric excita-tion of exchange spin waves, tall, can give signals of a higher level and get a good si g-nal/noise ratio for the signal convolution.

Authors and Affiliations

E. Kudinov

Keywords

Related Articles

Methodological aspects of treatment of a phenomenon diffraction of light

There is considered a methodological exclamation of phenomena of light diffraction with taking into account that light flow is photon flow.

Optimization of bandwidth of communication channels of corporate networks

Introduction. This article contains overview of the organization of communication between applications on the corporate network. It is stated that the main digital channel (channel B - 64 kbit/s) and the primary digital...

Evolution of a lumileds – from "cool light" Loseva to lighting of streets (part II)

In review are considered history development of semiconductor lumileds, done analysis up-to-date market lumileds, a new material and technology, are showed world tendencies and perspectives.

Two-step method of the measurement data processing of the high-sensitivity radiometric system

Introduction. The radiometry systems for registration low-intensity noise signals are widely used in science and technique. Automation of such apparatus allows to improve the precision of measurements and facilitate inte...

Analysis of character of dependence between pulse pressure in an artery and amplitude of a pulse signal non invasive registered

Dependences of amplitude of a pulse signal registered by a non-invasive method from pulse pressure in an artery are studied. It is shown, that for ranges of the pressures concerning to people, with an adequate accuracy i...

Download PDF file
  • EP ID EP309148
  • DOI 10.20535/RADAP.2012.51.122-131
  • Views 81
  • Downloads 0

How To Cite

E. Kudinov (2012). Use direct volume magnetostatic waves for convolver construction. Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування, 0(51), 122-131. https://europub.co.uk/articles/-A-309148