Use of deproteinizer to eliminate interference of high bilirubin on measurement of serum creatinine by the kinetic jaffe reaction

Journal Title: IP International Journal of Maxillofacial Imaging - Year 2018, Vol 5, Issue 2

Abstract

Introduction: Serum creatinine is a useful diagnostic parameter of kidney function. Its concentration reflects glomerular filtration rate. Because of negative interference of bilirubin over creatinine level, may mislead the clinician. The most common and serious problems in the determination of serum creatinine concentration by the kinetic Jaffe method is the negative interference by bilirubin. Materials and Methods: This cross sectional study was done on 160 patients which have high bilirubin level, taken from B. J. Medical College, Civil hospital, Ahmedabad from August 2013 to December 2013. These samples were studied for interference of total bilirubin on measurement of Serum creatinine level before and after treating with deproteinizer (trichloroacetic acid 0.55 mmol/ltr). Serum bilirubin and serum creatinine level were measured by modified Jendrassik & Groff’s method and kinetic Jaffe’s reaction respectively by using Erba XL-640 fully auto analyzer. Results: In this study significant difference was found in Serum Creatinine level with the samples of high bilirubin content before and after treating with deproteinizer (trichloroacetic acid) (p<0>Preprecipitation of albumin along with bilirubin by trichloroacetic acid beforehand is suggested as an approach to correct the bilirubin interference. Conclusion: From this study it is concluded that bilirubin have negative interference on serum creatinine level. And this is corrected by using deproteinizer trichloroacetic acid.

Authors and Affiliations

Vijaysinh Parmar, Hiren Sanghani, Asha Khubchandani

Keywords

Related Articles

Inverted impacted mesiodens – An incidental radiographic finding

Impacted tooth is one of the most common diagnoses done during routine dental check-up, especially the third molars in the teenagers and impacted permanent teeth in children during mixed dentition period. But inverted im...

Radiographic Quality of root fillings performed by dentists in Jammu and Kashmir, North India

The present study aimed at assessing the quality of root canal obturations being performed in the state of Jammu and Kashmir. Records of 1056 endodontically treated teeth from patients who visited the department of Conse...

Estimation of serum uric acid, urinary calcium-creatinine ratio and microalbuminuria in prediction of pre-eclampsia

Introduction: The present study was aimed at evaluating serum uric acid, urinary calcium to creatinine ratio and microalbuminuria as predictors of pre-eclampsia in asymptomatic pregnant females. Materials and Methods: 10...

Morphometric evaluation of Bizygomatic distance and maxillary sinus width as dimorphic tool- A CBCT study

Objectives: The objective of this study is to determine the age prediction on the basis of Bizygomatic distance, intermaxillary distance, Antero-Posterior diameter and maxillary sinus width. The bizygomatic distance and...

Radiotherapy for Head and Neck cancers-a review

Radiotherapy still remains an enigma in the treatment of Head and Neck cancers. Radiotherapy treatment planning of Head and Neck cancers pose a challenge due to its proximity to critical adjacent organs. This article bri...

Download PDF file
  • EP ID EP472751
  • DOI 10.18231/2394-6377.2018.0047
  • Views 45
  • Downloads 0

How To Cite

Vijaysinh Parmar, Hiren Sanghani, Asha Khubchandani (2018). Use of deproteinizer to eliminate interference of high bilirubin on measurement of serum creatinine by the kinetic jaffe reaction. IP International Journal of Maxillofacial Imaging, 5(2), 226-229. https://europub.co.uk/articles/-A-472751