Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt
Journal Title: Journal of Radiology and Imaging - Year 2018, Vol 3, Issue 1
Abstract
The availability of polytetrafluoroethylene (PTFE) covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS). Side effects of portosystemic shunting such as hepatic encephalopathy (HE) and worsening of hepatic function, however, remained a problem. To reduce HE, underdilatation of nitinol stents has been practiced for many years. However, as shown recently, underdilatation was a flop since, due to their intrinsic memory, nitinol stents always expanded to reach their nominal diameter of 8 or 10 mm. To overcome this problem and to be able to perform permanent shunts with a smaller diameter of < 8 mm, we studied the usefulness of a balloon-expandable, covered, metallic stent which allowed adjustment to any diameter between 5 and 12 mm. Methods: 30 patients with cirrhosis and symptomatic portal hypertension were included. The mean Child-Pugh score was 8 ± 2.17 patients had refractory ascites, 9 patients variceal bleeding and four patients other indications for the TIPS. Results: The TIPS was successfully implanted in all patients within 69.6 ± 21.8 min. The shunt reduced the portosystemic pressure gradient by 57.5 ± 14.2% with a mean stent diameter of 7.4 ± 1.0 mm (5 -10.3 mm). During a mean follow-up of 330 ± 249 days, shunt revision was necessary in 5 patients (17%), four of them had insufficient response and received stent dilatation and one patient had stent misplacement requiring a parallel shunt. Three patients (10%) developed HE. Conclusions: The covered, balloon-expandable stent could be placed accurately and allowed creation of adapted shunts with smaller diameters as usual. This resulted in a comparatively low rate of HE.
Authors and Affiliations
Martin Rössle, Lars Maruschke, Klaus Radecke, Daniel Grandt, Michael Schultheiss
Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt
The availability of polytetrafluoroethylene (PTFE) covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS...
Point of care ultrasound in cardiac arrest: A case report of PE in PEA arrest
Bedside ultrasound has become an integral part of cardiac arrest resuscitation, enabling the provider to identify potentially reversible conditions in real time. In the setting of pulmonary embolism, bedside ultrasound c...
The value of radiometry in sex assessment of bone fragments: A study on the radius in a modern Greek population
Objectives: This paper highlights the different applications of Digital Radiology in forensic sciences and proposes an alternative sex estimation method based on digital radiographs of the proximal and distal epiphysis o...
The hydrocele of canal of Nuck: Case report and review of the literature
The hydrocele of the canal of Nuck is a rare condition that results from the failure of obliteration of the distal portion of evaginated parietal peritoneum within the inguinal canal which forms a sac containing fluid. I...
A representative study of pediatric panoramic and cephalometric radiation exposure to organs of the head and neck
The purpose of this study was to measure juvenile patient radiation dose to organs of the head and neck during digital panoramic and cephalometric radiography using anthropomorphic CIRS phantoms at 5 and 10-years-old wit...