Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt

Journal Title: Journal of Radiology and Imaging - Year 2018, Vol 3, Issue 1

Abstract

The availability of polytetrafluoroethylene (PTFE) covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS). Side effects of portosystemic shunting such as hepatic encephalopathy (HE) and worsening of hepatic function, however, remained a problem. To reduce HE, underdilatation of nitinol stents has been practiced for many years. However, as shown recently, underdilatation was a flop since, due to their intrinsic memory, nitinol stents always expanded to reach their nominal diameter of 8 or 10 mm. To overcome this problem and to be able to perform permanent shunts with a smaller diameter of < 8 mm, we studied the usefulness of a balloon-expandable, covered, metallic stent which allowed adjustment to any diameter between 5 and 12 mm. Methods: 30 patients with cirrhosis and symptomatic portal hypertension were included. The mean Child-Pugh score was 8 ± 2.17 patients had refractory ascites, 9 patients variceal bleeding and four patients other indications for the TIPS. Results: The TIPS was successfully implanted in all patients within 69.6 ± 21.8 min. The shunt reduced the portosystemic pressure gradient by 57.5 ± 14.2% with a mean stent diameter of 7.4 ± 1.0 mm (5 -10.3 mm). During a mean follow-up of 330 ± 249 days, shunt revision was necessary in 5 patients (17%), four of them had insufficient response and received stent dilatation and one patient had stent misplacement requiring a parallel shunt. Three patients (10%) developed HE. Conclusions: The covered, balloon-expandable stent could be placed accurately and allowed creation of adapted shunts with smaller diameters as usual. This resulted in a comparatively low rate of HE.

Authors and Affiliations

Martin Rössle, Lars Maruschke, Klaus Radecke, Daniel Grandt, Michael Schultheiss

Keywords

Related Articles

Penetrating aortic ulcer manifesting as atypical chest pain

This is a case report of a penetrating aortic ulcer that presented as atypical chest pain. Imaging modalities for the diagnosis of aortic ulcers include computed tomography angiography, magnetic resonance angiography, an...

The value of radiometry in sex assessment of bone fragments: A study on the radius in a modern Greek population

Objectives: This paper highlights the different applications of Digital Radiology in forensic sciences and proposes an alternative sex estimation method based on digital radiographs of the proximal and distal epiphysis o...

A representative study of pediatric panoramic and cephalometric radiation exposure to organs of the head and neck

The purpose of this study was to measure juvenile patient radiation dose to organs of the head and neck during digital panoramic and cephalometric radiography using anthropomorphic CIRS phantoms at 5 and 10-years-old wit...

Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt

The availability of polytetrafluoroethylene (PTFE) covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS...

Third degree skin burns caused by a MRI conditional electrocardiographic monitoring system

Two unusual cases of third degree skin burns are reported using MRI approved electrocardiographic leads. This is very uncommon as it is most often the electrodes which are the source of heat related issues. Both patients...

Download PDF file
  • EP ID EP532920
  • DOI 10.14312/2399-8172.2018-1
  • Views 40
  • Downloads 0

How To Cite

Martin Rössle, Lars Maruschke, Klaus Radecke, Daniel Grandt, Michael Schultheiss (2018). Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt. Journal of Radiology and Imaging, 3(1), 1-5. https://europub.co.uk/articles/-A-532920