USING A LABVIEW AND FIELD POINT I/O MODULE FOR CATALYTIC ISOTOPIC EXCHANGE COLUMN CONTROL AND OPERATORS TRAINING
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2010, Vol 34, Issue 34
Abstract
This paper presents the main advantages of using the programmable automation controller (PAC) and LabVIEW software in the operation of an isotopic exchange column which is part of ETRF (experimental tritium removal facility) from ICIT Rm. Valcea. Taking in account the advantages of Compact FieldPoint for using in industrial control application (advanced embedded control, data logging, headless operation and Ethernet-based data acquisition) personnel are able to operate an experimental catalytic isotopic exchange column under manual or automatic control. The very friendly interface and an alarm management system help operators to manipulate the performance of the control loops (TIC, FIC, PIC) in order to improve the operation of the column. The operators can visualize all parameters of the process, to check/modify the conditions of the all control loops, to identify/change the on/off status of dynamic equipment. For young engineers is easy to understand the PAC graphic interface as well as to investigate control loops behavior during PID tuning process. The time required to train the engineers to operate and control the column by our PAC system is minimal. Also, in the paper it is presented a short description of the mathematical model (based on Shimizu equations) of the isotope transfer along the column length used for package evaluation performances during the experiment.
Authors and Affiliations
Ovidiu BALTEANU, Iuliana STEFAN, Ciprian BUCUR, Liviu STEFAN
Object Oriented Video Retrieval System based on Domain Ontologies
This paper presents a method for video information retrieval considering the frames extracted from the video sources through the segmentation of each key frame, the tracking of the salient objects and the domain on...
DESIGN AND PERFORMANCES OF COUPLING PASSIVE FILTERS IN THREE-PHASE SHUNT ACTIVE POWER FILTERS
The passive interface filter represents the link between the power grid and the shunt active filter. The interface filter is used both to obtain a good dynamic of the compensating current and to limit the high frequency...
The influence of ambient temperature on the potentiality of integrated systems for wind energy conversion into electricity
The main purpose of this paper is to view the influence of ambient temperature on the magnetic vector potential of a particular data structure, and thus the magnetic field distribution within the structure. The secondary...
THE STUDY OF ELECTRICAL PARAMETERS AND THE EXHAUST GAS ANALYSIS FOR A DOUBLE SPARK PLUG
The spark produced by a classical spark-plug does not always assure a fast and complete combustion of an air/fuel mixture into the combustion chamber of a thermal engine. This is the reason why we have done a long series...
Power Control and Energetic Performances of an Induction Heating System Destined for Drying of Current Transformers
This paper is concerned with the design of the power control system for a single-phase voltage source inverter feeding a parallel resonant induction heating load and the analyse of its energetic performances. The control...