USING ELECTRICAL IMPEDANCE TOMOGRAPHY IN LINEAR ARRAYS OF MEASUREMENT
Journal Title: Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska - Year 2017, Vol 7, Issue 1
Abstract
The article presents an application to the topology optimization in electrical impedance tomography using the level set method. The level set function is based on shape and topology optimization for areas with partly continuous conductivities. The finite element method has been used to solve the forward problem. The proposed algorithm is initialized using topological sensitivity analysis. Shape derivative and material derivative have been incorporated with the level set method to investigate shape optimization problems. The coupled algorithm is a relatively new procedure to overcome this problem. Using the line measurement model is very useful to solve the inverse problem in the copper-mine ceiling and the flood embankment.
Authors and Affiliations
Tomasz Rymarczyk
IDENTYFIKACJA SYSTEMÓW NIELINIOWYCH PRZY POMOCY KERNELOWEGO ALGORYTMU LMS Z OGRANICZENIEM ZASOBÓW
W artykule zaprezentowano zastosowanie nowej, nieliniowej wersji algorytmu LMS wykorzystującej funkcje kernelowe do identyfikacji systemów nieliniowych. Aby ograniczyć ilość wektorów nośnych, będących niezbędnym elemente...
OZE W BUDOWNICTWIE NISKOENERGETYCZNYM
W ostatnich latach kładzie się szczególny nacisk na produkcję energii elektrycznej w oparciu o źródła odnawialne (OZE). Celem artykułu jest przedstawienie podstawowej analizy ekonomicznej opłacalności wymiany instalacji...
MEASURING DATA ACQUISITION HARDWARE FOR ELECTRICAL IMPEDANCE TOMOGRAPHY
This article presents the design of the device with active electrodes to examine the flood embankment. There was discussed the method of determining the conductivity. The presented solution was based on electrical impeda...
SYMULACJA PRZEPŁYWU GRAWITACYJNEGO I ESTYMACJA JEGO PARAMETRÓW PRZY UŻYCIU ELEKTRYCZNEJ TOMOGRAFII POJEMNOŚCIOWEJ I SZTUCZNYCH SIECI NEURONOWYCH
W artykule opisano nowe podejście do monitorowania zmian charakterystycznych parametrów przepływu grawitacyjnego. Do nieinwazyjnego monitorowania procesu stosowana jest Elektryczna Tomografia Pojemnościowa (ECT). Sz...
ANALYSIS AND DETECTION POSSIBILITY OF THE PARTIAL DISCHARGES IN AIR INSULATED MEDIUM VOLTAGE SWITCHGEAR USING TRANSIENT EARTH VOLTAGE DETECTION
Modern switchgear increasingly use polymeric materials as insulation. Despite its numerous advantages they have limited resistance to partial discharge corrosion in some cases. In this paper noninvasive methods Tran...