Utilizing Internal Standard Responses to Assess Risk on Reporting Bioanalytical Results from Hemolyzed Samples

Journal Title: The AAPS Journal - Year 2015, Vol 17, Issue 5

Abstract

Bioanalytical analysis of toxicokinetic and pharmacokinetic samples is an integral part of small molecule drugs development and liquid chromatography—tandem mass spectrometry (LC-MS/MS) has been the technique of choice. One important consideration is the matrix effect, in which ionization of the analytes of interest is affected by the presence of co-eluting interfering components present in the sample matrix. Hemolysis, which results in additional endogenous components being released from the lysed red blood cells, may cause additional matrix interferences. The effects of the degree of hemolysis on the accuracy and precision of the method and the reported sample concentrations from hemolyzed study samples have drawn increasing attention in recent years, especially in cases where the sample concentrations are critical for pharmacokinetic calculation. Currently, there is no established procedure to objectively assess the risk of reporting potentially inaccurate bioanalytical results from hemolyzed study samples. In this work, we evaluated the effect of different degrees of hemolysis on the internal standard peak area, accuracy, and precision of the analyses of BMS-906024 and its metabolite, BMS-911557, in human plasma by LC-MS/MS. In addition, we proposed the strategy of using the peak area of the stable isotope-labeled internal standard (SIL-IS) from the LC-MS/MS measurement as the surrogate marker for risk assessment. Samples with peak areas outside of the pre-defined acceptance criteria, e.g., less than 50% or more than 150% of the average IS response in study samples, plasma standards, and QC samples when SIL-IS is used, are flagged out for further investigation.

Authors and Affiliations

Eliza N. Fung, Anne-Françoise Aubry, Alban Allentoff, Qin C. Ji

Keywords

Related Articles

In Vitro Studies are Sometimes Better than Conventional Human Pharmacokinetic In Vivo Studies in Assessing Bioequivalence of Immediate-Release Solid Oral Dosage Forms

Human pharmacokinetic in vivo studies are often presumed to serve as the “gold standard” to assess product bioequivalence (BE) of immediate-release (IR) solid oral dosage forms. However, when this general...

Use of Different Parameters and Equations for Calculation of IC50 Values in Efflux Assays: Potential Sources of Variability in IC50 Determination

The online version of this article (doi:10.1208/s12248-013-9554-7) contains supplementary material, which is available to authorized users.

Transporter and ion channel gene expression after caco-2 cell differentiation using 2 different microarray technologies

mRNA expression profiles had previously been measured in Caco-2 cells (human colonic carcinoma cells) using either custom-designed spotted oligonucleotide arrays or Affymetrix GeneChip oligonucleotide arrays. The Caco-2...

A Novel Ultrasensitive Hybridization-Based ELISA Method for 2-Methoxyphosphorothiolate MicroRNAs and Its In vitro and In vivo Application

MicroRNAs (miRNAs) are endogenous, small non-coding RNAs that bind to target mRNAs and regulate their expression. Recent evidence has indicated the involvement of miRNAs in human malignancies. It has been suggested that...

Applications of In Vitro–In Vivo Correlations in Generic Drug Development: Case Studies

In vitro–in vivo correlation (IVIVC) is a predictive mathematical model describing the relationship between an in vitro property and a relevant in vivo response. The main objective of an IVIVC is to serve as a su...

Download PDF file
  • EP ID EP680999
  • DOI  10.1208/s12248-015-9783-z
  • Views 34
  • Downloads 0

How To Cite

Eliza N. Fung, Anne-Françoise Aubry, Alban Allentoff, Qin C. Ji (2015). Utilizing Internal Standard Responses to Assess Risk on Reporting Bioanalytical Results from Hemolyzed Samples. The AAPS Journal, 17(5), -. https://europub.co.uk/articles/-A-680999