Vaginal Drug Delivery Systems for HIV Prevention
Journal Title: The AAPS Journal - Year 2009, Vol 11, Issue 1
Abstract
Microbicides have become a principal focus for HIV prevention strategies. The successful design of drug delivery systems for vaginal microbicide drug candidates brings with it a multitude of challenges. It is imperative that the chemical and physical characteristics of the drug candidate and its mechanism of action be clearly understood and considered to successfully deliver and target drug candidates efficiently. In addition, an understanding of the dynamic nature of the vaginal environment, the tissue and innate barriers present, as well as patient preferences are critical considerations in the design of effective microbicide products. Although the majority of drug candidates clinically evaluated to date have been delivered using conventional semisolid aqueous-based gel dosage forms, drug delivery system design has recently been extended to include advanced delivery systems such as vaginal rings, quick-dissolve films, and tablets. Ultimately, it may be necessary to develop multiple dosage platforms for a single active agent to provide users with options that can be used within the constraints of their social environment, personal choice, and environmental conditions.
Authors and Affiliations
Lisa Cencia Rohan, Alexandra B. Sassi
Utilizing Internal Standard Responses to Assess Risk on Reporting Bioanalytical Results from Hemolyzed Samples
Bioanalytical analysis of toxicokinetic and pharmacokinetic samples is an integral part of small molecule drugs development and liquid chromatography—tandem mass spectrometry (LC-MS/MS) has been the technique of...
Erratum to: Population Pharmacokinetics and Exposure-Uric Acid Analyses After Single and Multiple Doses of ABT-639, a Calcium Channel Blocker, in Healthy Volunteers
The online version of the original article can be found at 10.1208/s12248-014-9709-1.
A Bioequivalence Approach for Generic Narrow Therapeutic Index Drugs: Evaluation of the Reference-Scaled Approach and Variability Comparison Criterion
Various health communities have expressed concerns regarding whether average bioequivalence (BE) limits (80.00–125.00%) for the 90% confidence interval of the test-to-reference geometric mean ratio are sufficient...
Visualization of the lipid barrier and measurement of lipid pathlength in human stratum corneum
Detailed models of solute transport through the stratum corneum (SC) require an interpretation of apparent bulk diffusion coefficients in terms of microscopic transport properties. Modern microscopy techniques provide a...
A semiautomated approach to gene discovery through expressed sequence tag data mining: Discovery of new human transporter genes
Identification and functional characterization of the genes in the human genome remain a major challenge. A principal source of publicly available information used for this purpose is the National Center for Biotechnolog...