Validation of moving target doses using ArcCHECK Planned Dose Perturbation Algorithm

Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 0, Vol 9, Issue 2

Abstract

 The aim of the study is to use Planned Dose Perturbation (PDPâ„¢) measurement-guided reconstruction method to estimate dynamic 4D dose and evaluate both 3D dose and DVH changes caused by target motion resulting from respiration. Five patients of Ca lung were selected for the study. Target and Organ at risks were (OARs) delineated on 4DCT data set of each patient. Dose of moving target vs. stationary target were simulated and compared for OARs and target by analyzing 3D dose and DVH(Dose Volume Histogram).There was almost 3.5% higher target maximum doses measured with moving target after applying the target motion trajectory data as compared to the stationary target whereas OARs doses were comparable. The results, clinically signifies the importance of motion management in lung tumors.

Authors and Affiliations

P K Sharma, Roopam Srivastava, Laishram Suchitra

Keywords

Related Articles

The magnetic field Influence on the absorption threshold of VO2

The vanadium dioxide VO‚‚ is a material described as being intelligent because it can transit [1,2] from a reversible way of the semiconductor state to the metal state at a temperature θt = 68°C. When we are at a temper...

Assessment of Environment Traffic Noise Pollution in Uvwie Local Government Area of Delta State, Nigeria.

The assessment of environmental traffic noise pollution in Uvwie local government area of Delta State, Nigeria was carried out using a well calibrated portable digital sound level meter (Model  CEL-231).  The s...

Einstein's gravitation is Einstein-Grossmann's equations

While the philosophers of science discuss the General Relativity, the mathematical physicists do not question it. Therefore, there is a conflict. From the theoretical point view the question of precisely what Einstein di...

The properties of Bessel-type fractional derivatives and integrals

The fractional integrals of Bessel-type Fractional Integrals from left-sided and right-sided integrals of fractional order is established on finite and infinite interval of the real-line, half axis and real axis. The Bes...

Download PDF file
  • EP ID EP653734
  • DOI 10.24297/jap.v9i2.1392
  • Views 67
  • Downloads 0

How To Cite

P K Sharma, Roopam Srivastava, Laishram Suchitra (0). Validation of moving target doses using ArcCHECK Planned Dose Perturbation Algorithm. JOURNAL OF ADVANCES IN PHYSICS, 9(2), 2348-2354. https://europub.co.uk/articles/-A-653734