“Value of 3D Stir Gated MRI Sequence in Cardiac and Chest Imaging with 3T MRI”: Initial Experiences

Journal Title: Journal of Clinical and Diagnostic Research - Year 2019, Vol 13, Issue 1

Abstract

ABSTRACT Introduction: Cross-sectional imaging has been increasingly used in recent years for cardiac and chest evaluation as multiplanar imaging gives excellent image characterization. Multiplanar imaging with excellent soft tissue contrast without radiation risks in MRI signifies its major role in cardiac and chest imaging. Aim: To evaluate the value of 3-Dimensional T2-Weighted Short Inversion Time Inversion Recovery (3D-T2-STIR) gated sequence in cardiac and chest MR imaging. Materials and Methods: A prospective cross-sectional study was conducted in which 41 adult patients who came for chest and cardiac MRI were included. All our patients were imaged on a 3-T clinical scanner and obtained T2-weighted SPACE STIR gated sequence in addition to routine sequences. The image qualities of 3D-T2-SPACE STIR sequences were compared with routine MRI sequences and were scored by two experienced radiologist in blinded fashion as good, fair and poor. Scan time consumption of 3D-T2-SPACE STIR sequences and routine MRI sequences were also done. Results: A 3D T2 SPACE STIR sequences demonstrated comparable image quality in all patients. The level of agreement between the two radiologists on the image qualities of 3D-T2-SPACE STIR sequences was excellent. In patients with renal failure and pregnant patients where contrast studies and CT is contraindicated 3D SPACE STIR T2 imaging adds value in diagnosing pulmonary thromboembolism, congenital heart disease, bronchiectasis and consolidation with very less sequence acquisition time, ranging from 1 to 3 minutes. Conclusion: A 3D SPACE STIR MRI sequence is a useful adjunct in cardiac and chest imaging especially in renal failure and pregnant patients where contrast is contraindicated and also time conserving in these patients.

Authors and Affiliations

Geetha Kandasamy, S Babu Peter, R Bharathi Priya

Keywords

Related Articles

Study of Glycated Haemoglobin (HbA1c) In Non-Diabetic Subjects with Subclinical Hypothyroidism

Introduction: India has the higher prevalence of prediabetes, diabetes and hypothyroidism. Subclinical Hypothyroidism (SH) is more prevalent in the females than in the males. Studies have shown the elevated HbA1c in the...

Predictors of Past Quit Attempts and Length of Abstinence among Waterpipe Smokers in Lebanon

ABSTRACT Introduction: The popularity of waterpipe smoking is dramatically increasing in Lebanon, reaching 36.9%, the highest among countries in the region, with a false belief that waterpipe is less dangerous and toxic...

Pulmonary Embolism Following Varicella Infection

ABSTRACT Venous Thromboembolism (VTE) post varicella infection is a rare complication owing to vascular endothelial damage, accelerated atherosclerosis and antibody-mediated hypercoagulable state. Pulmonary Embolism (PE)...

The Association between Cariogenic Factors and the Occurrence of Early Childhood Caries in Children from Salem District of India

Introduction: Various aetiological factors for Early Childhood Caries (ECC) have been suggested in literature, but the role of each factor has been disputed in various studies. Aim: To evaluate the association between EC...

Rising Incidence of Non-albicans Candida and Changing Susceptibility Pattern of Bloodstream Candida Isolates in Neonates

Introduction: Importance of Candida species in nursery and paediatric Intensive Care Units (ICUs) is increasingly being recognized and nowadays isolates resistant to antifungal therapy are on the rise. They account for 9...

Download PDF file
  • EP ID EP556426
  • DOI 10.7860/JCDR/2019/37604.12443
  • Views 84
  • Downloads 0

How To Cite

Geetha Kandasamy, S Babu Peter, R Bharathi Priya (2019). “Value of 3D Stir Gated MRI Sequence in Cardiac and Chest Imaging with 3T MRI”: Initial Experiences. Journal of Clinical and Diagnostic Research, 13(1), 6-9. https://europub.co.uk/articles/-A-556426