VHDL DESIGN FOR IMAGE SEGMENTATION USING LOG GABOR FILTER FOR DISEASE DETECTION

Journal Title: JOURNAL OF ADVANCES IN CHEMISTRY - Year 2016, Vol 12, Issue 19

Abstract

Tonsillitis, Tumor and many more skin diseases can be detected in its early-state and can be cured. For this a new idea for efficient Gabor filter design with improved data transfer rate, efficient noise reduction, less power consumption and reduced memory usage is proposed in this paper. The filter design is suitable for detecting the early stages of disease using textural properties of anatomical structures. The code for Log Gabor filter will be developed in VHDL using Modelsim and then implemented on SPARTAN-3E FPGA kit. These systems must provide both highly accurate and extremely fast processing of large amounts of image data.

Authors and Affiliations

P. R. Gomathi, A. Arun

Keywords

Related Articles

FUZZY COST OVERRUN ANALYSIS MODEL FOR CONSTRUCTION PROJECT

Now a day’s many factors which affect the productivity in construction project. Due to this delay factors time and cost overrun in a project. In this research helps to identify the most important factors that affect th...

Mechanical Properties of Randomly Oriented Calotropis Gigantea Fiber-Reinforced Phenol Formaldehyde Biocomposites

Mechanical properties such as tensile, flexural and impact, of randomly oriented Calotropis Gigantea Fiber (CGF) -reinforced Phenol Formaldehyde (PF) biocomposites were studied based on the five different fiber loadings...

The Potential of Some Non-Conventional Vegetable Oils in Biodiesel Applications

This work studied the potentials of some non-conventional oils biodiesel as an alternative to biodiesel made from a conventional seed oil (palm kernel oil), and petroleum-based diesel. The fruits of three non-conventiona...

Highly selective potentiometric determination of Fe(III) ions using Tris-(1,2-diiminocyclohexylmethyl-5-Cl-2-hydroxyl benzaldehyde) based membrane electrode

A novel ion-selective poly(vinyl chloride) membrane sensor for Fe(III) ions based on Tris-(1,2-diiminocyclohexylmethyl-5-Cl-2-hydroxyl benzaldehyde) are reported in this paper. The electrode exhibits a good potentiometri...

Synthesis, Characterization and evaluation of new

ABSTRACT A new  polymer surfactant derived from cis-1,4-cyclohexane bis(methylamine) and ethylenediamintetraacetic acid [2,2'-(1,12-bis(4-(aminomethyl)cyclohexyl)-3,10-dioxo-2,5,8,11-tetraazadodecane-5,8-diyl) diacetic...

Download PDF file
  • EP ID EP652998
  • DOI 10.24297/jac.v12i19.5370
  • Views 179
  • Downloads 0

How To Cite

P. R. Gomathi, A. Arun (2016). VHDL DESIGN FOR IMAGE SEGMENTATION USING LOG GABOR FILTER FOR DISEASE DETECTION. JOURNAL OF ADVANCES IN CHEMISTRY, 12(19), 5184-5188. https://europub.co.uk/articles/-A-652998