Visual and Refractive Outcomes after Cataract Surgery with a Monofocal Intraocular Lens Using Two Optical Biometers: IOL Master and Aladdin with EyeCeeOne Preloaded IOL
Journal Title: Journal of Ophthalmology and Advance Research - Year 2021, Vol 2, Issue 2
Abstract
Purpose: To report visual and refractive outcomes obtained with a preloaded, hydrophobic, monofocal, intraocular lens in two series of patients with two different optic biometers for power calculation. Methods: Two comparable series of 38 eyes that underwent cataract surgery, followed by EyeCeeOne Preloaded IOL implantation, in two different centers from March 2018 to march 2019 are retrospectively studied. Two different optic biometers (IOLMaster and Aladdin), one in each center, were used to measure the eyes of the patients and calculate pseudophakic IOL power with SRK/T formula. Exclusion criteria included: corneal astigmatism larger than 1.5D, intraoperative complications (i.e. posterior capsular tear, vitreous loss) cases in which capsular tension ring was implanted, cases with postoperative complications unrelated to IOL placement (i.e. macular edema, endothelial failure). Statistical comparisons were made using the unpaired Student t- Test assuming heteroscedasticity. Results: Uncorrected distance visual acuity in decimal notation was 0.87±0.13 in Aladdin group and 0.84±0.19 in IOLMaster group (p=0.409), mean spherical equivalent (SE) obtained was -0.21±0.34 and -0.13±0.43 (p=0.359) and the mean difference among predicted and obtained SE was -0.02±0.34 and 0.10±0.39 (p=0.179) respectively. 84.2% and 81.5% of patients were among ±0.5D of SE respectively. Conclusion: In this study the EyeCeeOne Preloaded IOL proved to be a safe and effective IOL for pseudophakia. Predictable and satisfactory refractive outcomes can be achieved using two different biometers. Further studies with extreme axial lengths are needed to evaluate IOL performance in those situations.
Authors and Affiliations
Alberto Parafita-Fernandez*, Maria N Moraña, Jorge García-Borregón, Martin Jabif, Joao C Soares da Costa, Alba Feal, Eloy Viso
Visual Outcomes of Secondary Lens Implants in Children with Different Etiologies
Aim: This study investigated visual outcomes and factors that impact vision in children receiving secondary Intraocular Lens (IOL) implants. Methods: Children who had traumatic or congenital cataracts and underwent se...
Epidemioclinical and Histological Profile of Malignant Ocular Tumors at University Hospital Center of Bouake
Objective: To describe the epidemiological, clinical and histopathological aspects of malignant tumors in the Gbêkê region. Materials and methods: Retrospective cross-sectional descriptive study conducted in the ophth...
Pentacam Anterior Float Anomaly Due to Band Shaped Keratopathy
A 27 year old female with best corrected visual acuity 20/60 and 20/30 in the right (OD) and left (OS) eyes respectively presented to us for refractive surgery. Refractive errors were -9.25 D and -7 D spherical equival...
Results of Minimally Invasive Device TrabEx+ in Patients with Primary Open Angled Glaucoma
Purpose: The aim of our prospective study is to present the results of trabecular meshwork excision with the minimally invasive device TrabEx+ in patients with Primary Open-Angle Glaucoma (POAG). Methods: Patients dia...
Cosmetic Laser Related Retinal Injuries
Cosmetic industries are booming in many Asian cities where the uptake of laser treatment is becoming more frequent. The close proximity of the cosmetic laser handheld probe to the ocular adnexa is at risk of jeopardizi...