Voltage Stability Assurance Based Optimal Location and Sizing of Distribution Generation in Radial Distribution System
Journal Title: IOSR Journals (IOSR Journal of Electrical and Electronics Engineering) - Year 2018, Vol 13, Issue 4
Abstract
In general during light loading conditions, the feeder voltage may raise significantly and vice versa for heavy loading conditions. In addition, the increasing trend of different Distribution Generation (DG) is focusing the need of feeder voltage regulation within the specified limits due to reversal of power flow from load centers to the generation centres. In this paper, the locations of multiple types of DG systems are placed optimally based on voltage stability index and the optimal sizing of DG systems are obtained using Time– Variant Acceleration Coefficient–Particle Swarm Optimization (TVAC–PSO). The proposed methodology is applied on a standard 12-bus radial distribution system and the simulation results are validating the proposed methodology for real-time applications.
Authors and Affiliations
Vericherla N Malleswari, K. Chandra Sekhar
UAV Heading Control in Windy and Turbulent Conditions Using Reinforcement Learning
Due to the high non-linearity and coupling of a system model in an Unmanned Aerial Vehicle, UAV, the control of the heading has been a challenging task especially under windy and turbulent conditions. In this paper an on...
Novel Three Phase Five Level Inverter with Reduced Number of Power Electronics Components
Novel three phase five level inverter with reduced number of power electronics components are introduced. This inverter consists of typical three phase two level-bridge inverter with three bidirectional switches and two...
Hardware Implementation of Intelligent Controllers for Elementary Luo Converter
Positive output elementary Luo converter performs the conversion from positive DC input voltage to positive DC output voltage. Since Luo converters are non-linear and time-variant systems, the design of high performance...
A Fault Detection and Protection Scheme for A 200 MVA Transformer Using Fuzzy Logic
The paper elucidates a fault detection and protection scheme for a 200MVA transformer using Fuzzy logic. Fuzzy logic (FL) tool box in MATLAB/ SIMULINK software was utilized in the simulation system that diagnosed transfo...
Mat lab Simulation Procedure for Design of Micro -HydroElectric Power Plant
The design procedure of micro-hydro power plant was implemented by Matlab Simulink computer program to calculate all the power plant parameters. The choice of turbine type was depending mainly on the site head and rate o...