Water quality deterioration modeling in aged distribution mains: A case study in Addis Ababa, Ethiopia

Journal Title: Environmental Health Engineering and Management Journal - Year 2024, Vol 11, Issue 2

Abstract

Background: Water quality deterioration is becoming a serious challenge for water utility corporations supplying treated water through the use of a centralized distribution system. After water leaves the treatment plant and enters the distribution system, it is subjected to numerous complex physical, chemical, and biological changes. This study aimed to investigate the major physical factors deteriorating water quality in an aged distribution system. Methods: Deterioration modeling was undertaken using an EPANET computer program. For model calibration processes, data collected from field measurements were used. Descriptive statistics were employed to analyze the data. Water age and residual chlorine were selected parameters to investigate the deterioration level. The identification of major factors posing water quality changes was undertaken by examining distinct physical and operational settings. Results: The maximum water-age variation obtained between two extreme water-use periods was 21.97%. In the same way, the maximum residual chlorine concentration variation obtained was 11.68%. On the contrary, with tested extreme pipe sizes in the study, the maximum water-age variation obtained was only 0.93%. Whereas, the obtained maximum residual chlorine concentration variation between the two extreme pipe sizes was 21.03%. Conclusion: Water use variation poses more water quality degradation than pipe geometry. Water age in aged distribution is rarely influenced by conditions of pipe geometry.

Authors and Affiliations

Chali Dereje Kitila

Keywords

Related Articles

Accomplishment of water safety plan using quality assurance tool in 2020-2021: A case study in a western city of Gilan province, Iran

Background: Water safety plan is a systematic approach to ensure the quality of water delivered to consumers from catchment to consumption. Methods: This study was conducted on the groundwater system of Talesh, Gilan, i...

Bioremediation of methyl tertiary-butyl ether (MTBE) by three pure bacterial cultures

Background: Bioremediation of groundwater and soil contamination is more economical than physicochemical remediation. The present study focused on the bioremediation capability of two bacterial species (Klebsiella planti...

The effect of economic factors on the quality of the environment in African countries: An application of panel quantile regressions

Background: To mitigate the climate change, several researches have been conducted to determine the determinant factors of CO2 emissions. Nonetheless, a consensus was failed to reach yet on the issue because many of th...

Modeling the concentration of suspended particles by fuzzy inference system (FIS) and adaptive neuro-fuzzy inference system (ANFIS) techniques: A case study in the metro stations

Background: Today, the usage of artificial intelligence systems and computational intelligence is increasing. This study aimed to determine the fuzzy system algorithms to model and predict the amount of air pollution b...

Performance evaluation of adaptive neuro-fuzzy inference system for modelling dissolved oxygen of Kubanni Reservoir: A case study in Zaria, Nigeria

Background: Water quality evaluation require arduous laboratory and statistical analyses comprising of sample collection and sometimes transportation to laboratories, which may be expensive. In recent years, there has...

Download PDF file
  • EP ID EP738994
  • DOI 10.34172/EHEM.2024.13
  • Views 46
  • Downloads 0

How To Cite

Chali Dereje Kitila (2024). Water quality deterioration modeling in aged distribution mains: A case study in Addis Ababa, Ethiopia. Environmental Health Engineering and Management Journal, 11(2), -. https://europub.co.uk/articles/-A-738994