Wear Analysis of Hip Joint Prosthesis: A Review

Abstract

Total hip replacement (THR) is one of the most successful applications of biomaterials in the medical industry. In THR, a spherical head connected to the femoral stem articulates against a spherical cup/liner attached to the pelvic bone. The tribological performance of artificial hip joints is a critical issue for their success, because adverse tissue reaction to wear debris causes loosening and failure. The wear of the bearing surfaces of hip joint prostheses is a key problem causing their primary failure. Many studies on wear of hip prostheses have been published in the last 10 years. Theoretical/ numerical models have been proposed for investigating geometrical and material parameters also. This detailed study of wear analysis of hip joint is carried out highlighting anatomy of hip joint, wear and artificial implants such as hard on hard and hard on soft implants for hip joint. It aims to obtain in depth understanding of wear of bearing couples of artificial hip joint due to varying contact stresses under physiological gait loading.

Authors and Affiliations

Tushar V Kavatkar, Milind S Kirkire, Harshal Salvi, Dipak Patil,

Keywords

Related Articles

UPFC Based Wind Energy Efficient System

The rapid growth of wind power systems worldwide will likely see the integration of large wind farms with electrical network that are series compensated stable transmission of bulk power. Using Flexible AC Transmission...

Thermal and Mechanical Analysis on Palm Briquettes

Now we are getting more solid municipal and agricultural wastes. If we can utilize these solid wastes into useful energy resources, then the utilization of these resources along with renewable resources may increase the...

A Study on the Strength Development of Geopolymer Concrete using GGBS at Ambient Temperature

Today Concrete usage around the globe is second only to water. The demand of concrete is increasing day by day and cement is used for satisfying the need of development of infrastructure facilities. The production of on...

Hierarchical Energy Management System for Smart Buildings

The Hierarchical energy management allows generation facilities to be run more efficiently with the rapid introduction of network enabled digital technology. This technology offers exciting opportunities to increase the...

Power Factor Correction by Implementation of Reactive Power Compensation Methods of 220 KV Substation MPPTCL Narsinghpur

In an electric power system, which is AC (alternating current) by nature forms the most advantageous, the equipments and other industrial inductive loads draw reactive power and suffer with the problem of power factor i...

Download PDF file
  • EP ID EP21595
  • DOI -
  • Views 258
  • Downloads 3

How To Cite

Tushar V Kavatkar, Milind S Kirkire, Harshal Salvi, Dipak Patil, (2016). Wear Analysis of Hip Joint Prosthesis: A Review. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 4(2), -. https://europub.co.uk/articles/-A-21595