Wearable multi-sensor system for embedded body position and motion analysis during cycling

Journal Title: Journal of Science and Cycling - Year 2014, Vol 3, Issue 2

Abstract

Purpose: The purpose of this study was to validate the AREM system in laboratory conditions. AREM is an embedded electronic system for motion tracking and movement analysis, based on Micro Electro Mechanical Systems (MEMS) sensors and a reconfigurable hardware/software electronic architecture including FPGA + PSoC embedded boards for real time acquisition and signal processing. Methods: AREM sensors were installed on cyclist before performing on a test in which other measurements were made to analyse efficiency of standing position. The position of cyclists during whole test was measured by both AREM and a Kinematic Arm and verified by video systems. The protocol included 13 elite participants on a motorised treadmill with their own bike during which they rode in a randomized order seated vs. standing positions with several slopes (5, 7.5 and 10%) and intensities (3.8, 4.2 and 4.6 W.kg-1). GE was calculated for each condition using the ratio of power output (PO) measured with a Powertap G3 hub (CycleOps, Madison, USA) and the oxygen uptake (VO2) measured with a portable gas analyzer (Metamax 3B, Cortex, Leipzig, Germany). Results & Discussion: The synchronised data of 8 inertial sensors was retrieved and combined to obtain joint positions of shoulders (2), waist (3), middle and lower trunk (2) on cyclist. 1 sensor was installed under the saddle of the bike. The position data was compared between the two systems, and result on validation of AREM for 3-axis displacements (up to 40cm on X axis). We also compared the accelerations (+/- 2 m.s-2 seated to +/- 6 m.s-2 in standing position, errors up to 10% between both systems), power and energies for each cyclist during test steps (kinetic energies variation from 1.1 J/Kg to 3 J/Kg in a pedal stroke). Moreover, the acceleration and orientation data on cyclist and bike revealed different approaches on effort management during the test, and were compared to videos to obtain sensors data according to different “standing position” techniques. This data is an interesting indicator of the cyclist fatigue during a test, and is being crossed with PO and VO2 data. Conclusion: The validation of AREM system offers the possibility to extend our measures on real cycling locomotion in outdoor conditions, replacing the kinematic arm with AREM.Despite the 3D movement analysis of the cyclist on a standard protocol, first results suggest a position adjustment according to the technique of each cyclist, but also an impact of the mechanical response of the system tires-bike frame. The main perspective of these works is to include the Structure Health Monitoring analysis (SHM) on bike and to synchronise it with the cyclist activity and motion analysis during outdoor training. With both data, we expect to develop a reliable monitoring and optimisation system of the bike-cyclist couple in different course conditions.

Authors and Affiliations

A Valade| LAAS-CNRS, Toulouse, France, G Soto Romero| LAAS-CNRS, Toulouse, France, C Escriba| LAAS-CNRS, Toulouse, France, A Bouillod| EA4660, C3S Health - Sport Department, Sports University, Besancon, France., J Pinot| EA4660, C3S Health - Sport Department, Sports University, Besancon, France.Professional Cycling Team FDJ.fr, J Cassirame| EA4660, C3S Health - Sport Department, Sports University, Besancon, France., JY Fourniols| LAAS-CNRS, Toulouse, France, F Grappe| EA4660, C3S Health - Sport Department, Sports University, Besancon, FranceProfessional Cycling Team FDJ.fr.

Keywords

Related Articles

Track tales: A narrative exploration of within-career transition in sprint cycling

Background: Although a considerable amount of literature is dedicated to the final transition of retirement, relatively little research focuses on within-career transition. Such a dearth of research may originate from th...

An updated approach to incremental cycling tests: Accounting for internal mechanical power

Incremental cycling tests are typically used to determine blood lactate thresholds to monitor training and to form the basis for prescribing training zones. With minimal additional post-processing of the data normally co...

Effect of feedback on cycling performance in a 4‐kilometres laboratory time trial

Background: Nowadays performance data (e.g. power, speed, cadence) are available to cyclists in real time. The availability and manipulation of the data can be used to change activity parameters (e.g. pedaling dynamics)...

Computer modelling of energy turnover and body temperatures in elite cyclists during climbing: steep, steeper, Angliru; cold, colder, Gavia

Climbing very steep mountain roads (e.g. Monte Zoncolan, Angliru) or high passes with sub- zero temperatures at the summit (e.g. Gavia, Stelvio) imposes intense stress on the physiological system during professional bicy...

Within-individual haemoglobin variation and the athlete biological passport: a longitudinal investigation of 13,887 haemoglobin concentration readings in elite athletes

The Athlete Biological Passport (ABP), introduced by the Union Cycliste Internationale (UCI) in 2008, has proven a critical tool for the reduction of doping cases. The ABP estimates individual reference ranges for haem...

Download PDF file
  • EP ID EP2879
  • DOI -
  • Views 378
  • Downloads 20

How To Cite

A Valade, G Soto Romero, C Escriba, A Bouillod, J Pinot, J Cassirame, JY Fourniols, F Grappe (2014). Wearable multi-sensor system for embedded body position and motion analysis during cycling. Journal of Science and Cycling, 3(2), 0-0. https://europub.co.uk/articles/-A-2879