Will the Number of Replicates In Bootstrapped Data Alter the Bioequivalence Results?

Journal Title: UNKNOWN - Year 2015, Vol 4, Issue 2

Abstract

"The estimation of 90% parametric confidence intervals (CIs) of mean Cmax and AUC’s ratios in bioequivalence (BE) tests are based upon the assumption that formulation effects of test and reference drug are comparable. Bootstrap nonparametric 90% CIs of formulation effects were estimated with the different replicates (500, 1000, 2000 and 5000) and then compared with the parametric 90% CIs of the original datasets. Histograms and density curves of formulation effects obtained from resampled datasets were similar to those of normal distribution. Currently, the 80 - 125% rule based upon the parametric 90% CIs is widely accepted under the assumption of normally distributed formulation effects in log-transformed data. However, number of replicates in the bootstrapping has significant impact on altering the study results "

Authors and Affiliations

Keywords

Related Articles

High Boost Ratio Hybrid Transformer DC-DC Converter for PV Grid Applications

Attempts were made by scientists for utilizing solar power. Solar drives, solar water heater, solar concentrators are some examples. Recently because of energy shortage green gas effect, attention was given for generatin...

Prevalence of Amblyopia in Children Aged from 5-15 Years in Rural Population Kurnool Dist. Andhra Pradesh, India

study of school children in rural area of Kurnool district by using E chart, streak retinoscope, and subjective correction, the children not improving refered to Govt.Regional Eye Hospital for final diagnosis. Among 1...

Comparative Study on the Use of Widal Test and Stool Culture in the Laboratory Diagnosis of Salmonella Infection in Adult and Children in Jos Metropolis, Plateau State, Nigeria

"Background: Salmonella infection is a common bacteria disease that causes enteric fever in humans which are shed in faeces. Presently, Widal test, Stool culture, blood culture and urine culture are the most diagnostic m...

Chronobiology of rate pressure product in young adults

Cardiac events are known to precipitate at specific hours of the day implying that a circadian rhythm of myocardial oxygen demand may exist. Rate - pressure product (RPP) is regarded as a surrogate measure of myocardial...

Download PDF file
  • EP ID EP356207
  • DOI -
  • Views 82
  • Downloads 0

How To Cite

(2015). Will the Number of Replicates In Bootstrapped Data Alter the Bioequivalence Results?. UNKNOWN, 4(2), -. https://europub.co.uk/articles/-A-356207