Winding Fault Detection in Power Transformer by SFRA with DOBLE M5100

Abstract

The Doble M5100 is a robust and field proven instrument for detection of hidden fault in Power Transformer uses technique called Sweep Frequency Response Analysis (SFRA). SFRA is a tool that can give an indication of core or winding movement in Power Transformer this is done by performing a measurement, albeit a simple one, looking at how well a transformer winding transmits a low voltage signal that varies in frequency, Just how well the transformer does this is related to its impedance, the captive and inductive elements of which are intimately related to physical construction of transformer, Changes in frequency response as measured by SFRA technique may indicate a physical change inside the transformer, the cause of which then need to be identified and investigated. M5100 allow us to see inside the transformer and detect even suitable changes in the mechanical structure of the core and winding.

Authors and Affiliations

Shivangi Rai

Keywords

Related Articles

Visual Secret Sharing (VSS) of Digital Images by Diverse Media using Stegnography

Visual cryptography (VC) is a technique that encrypts secret image in meaningful images. The meaningful images can be photos or hand-painted pictures in digital form or in printed form. N such shares can be used. VC is u...

Literature Survey on Attribute Based Encryption (ABE)

During this Paper, we tend to show however Anony Control-F extends the User Revocation rule with a data structure to enhance quantify ability and adaptability whereas at a similar time inherits the feature of fine-graine...

Voice Call Using Arduino and GSM Module

In this article we demonstrate one of the possible ways to make a voice call using Arduino tools and GSM module. A Numeric keypad is built through which the contact number is dialed which is recognized by the Arduino boa...

Analysis of effect of yogic exercise on Static and Dynamic flexibility amoung school students

The authors in thier research want to investigate the efect of three weeks exercise amoung students of XI(Boys and Girls)of DAV school in Ajmer. The pre and post test had taekn by the author by using Dynamicflexibility t...

Phytochemical Studies on Terminalia Arjuna Root

To cure human diseases, medicinal plants have been a major source of therapeutic agents since ancient time. Terminalia arjuna is one kind of widely used medicinal plant throughout India and used in various indigenous sys...

Download PDF file
  • EP ID EP221630
  • DOI -
  • Views 111
  • Downloads 0

How To Cite

Shivangi Rai (2015). Winding Fault Detection in Power Transformer by SFRA with DOBLE M5100. International journal of Emerging Trends in Science and Technology, 2(3), 2147-2157. https://europub.co.uk/articles/-A-221630