2-Ethylhexyl acrylate. Determining 2-ethylhexyl acrylate in workplace air with gas chromatography with flame ionization detection (GC-FID) płomieniowo-jonizacyjną

Journal Title: Podstawy i Metody Oceny Środowiska Pracy - Year 2014, Vol 30, Issue 1

Abstract

A new procedure has been developed for the assay of 2-ethylhexyl acrylate with gas chromatography. The method is based on: the adsorption of 2-ethylhexyl acrylate on activated charcoal and desorption with 5% acetic acid in carbon disulfide. The resulted solutions are analysed with gas chromatography with flame ionization detection. The working range of the analytical method is 30 ÷ 750 µg/ml (3 ÷ 75 mg/m3 for a 10-L air sample). Limit of quantification: 7.0 µg/ml. The developed method of determining 2-ethyl-hexyl acrylate has been recorded as an ana-lytical procedure (see Appendix).

Authors and Affiliations

Agata Wziątek , Katarzyna Janoszka, Jan Gromiec

Keywords

Related Articles

Metotreksat. Oznaczanie w powietrzu na stanowiskach pracy

Metotreksat (MTX) w temperaturze pokojowej występuje w postaci krystalicznego proszkuo intensywnej żółtej barwie i delikatnym zapachu, charakterystycznym dla związków aromatycznych.Związek ten stosuje się jako lek cytost...

Buta-1,3-diene. Documentation of proposed values of occupational exposure limits (OELs)

Buta-1,3-diene is a gas used in the production of thermoplastic resins, elastomers and synthetic rubber. Buta-1,3-diene is absorbed mainly in the respiratory tract and then metabolized to monoepoxide – 1,2-epoxybut-3-ene...

Calcium hydroxid. Determination in workplace air

Calcium hydroxide is a white color solid. It is used in construction, chemical industry, water purification and wastewater treatment, flue gas desulphurization. Calcium hydroxide causes serious damage to the eyes, irrita...

Fenylohydrazyna i jej sole – w przeliczeniu na fenylohydrazynę. Dokumentacja proponowanych dopuszczalnych wielkości narażenia zawodowego

Fenylohydrazyna w temperaturze pokojowej jest bezbarwną lub żółtą oleistą cieczą, a w niższych temperaturach występuje w postaci krystalicznej. Fenylohydrazyna jest stosowana w syntezie organicznej jako silny środek redu...

Harmonizing measurement strategies for assessing exposure to nano-objects and their agglomerates and aggregates (NOAA)

This article discusses harmonizing methods of measurements done in real conditions at work-stations in the context of assessing exposure and occupational risk and selecting appropriate protection measures. It is importan...

Download PDF file
  • EP ID EP224634
  • DOI -
  • Views 81
  • Downloads 0

How To Cite

Agata Wziątek, Katarzyna Janoszka, Jan Gromiec (2014). 2-Ethylhexyl acrylate. Determining 2-ethylhexyl acrylate in workplace air with gas chromatography with flame ionization detection (GC-FID) płomieniowo-jonizacyjną. Podstawy i Metody Oceny Środowiska Pracy, 30(1), 55-67. https://europub.co.uk/articles/-A-224634