A Biomechanical Comparison between Taylor’s Spatial Frame and Ilizarov External Fixator

Journal Title: Malaysian Orthopaedic Journal - Year 2014, Vol 8, Issue 2

Abstract

Taylor’s spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4 threaded rods, and 6 threaded rods were compared to a standard IEF rings with 4 threaded rods. Compression and torsional loading was performed to the frame as well as construct with Polyvinylchloride tubes. TSF rings with 4 tube connectors had the highest stiffness (3288 N/mm) while TSF rings with 6 struts was the least stiff. The situation was reversed for torsion where TSF rings with 6 oblique struts had the highest torsional stiffness (82.01 Nm/Degree) and frame Ilizarov rings with 4 threaded rods the least. Standard TSF construct of two ring with 6 oblique struts have better torsional stiffness and lower axial stiffness compared to the standard IEF.

Authors and Affiliations

BB Tan, R Shanmugam, YP Chua, Hossain G, A Saw

Keywords

Related Articles

Tuberculosis of Wrist Presenting as Scaphoid Fracture: A Case Report

The scaphoid is an uncommon site for tuberculous infection. Clinical features and radiographic findings are not necessarily helpful and may lead to a delay in diagnosis and therefore poor treatment results. We report her...

Epiphyseal involvement in Erdheim-Chester disease: an under-reported phenomenon

Involvement of the epiphysis has been described in Erdheim-Chester disease. Dion E et. al (2006) described periostitis and partial epiphyseal involvement in their series of 11 patients which was appreciated radiologicall...

Improvised Suction Apparatus for Closure of Large Soft Tissue Deficit

Background: Vacuum Assisted Closure (VAC) is an established method that can be used in order to cover for soft tissue defects. This study focuses on the use of a modified suction machine in the form of an aquarium pump a...

Spontaneous Septic Monoarthritis of the Scaphoidtrapezium Joint Presenting as Septicaemia and Death in an Elderly Female: A Case Report

Primary involvement of carpal bones in septic arthritis is a rare event. We report here a case of idiopathic septic arthritis with isolated involvement of the scaphoid-trapezium joint. An elderly patient presented with c...

Use of the Tip-Apex Distance in predicting Dynamic Hip Screw Cut Out in Intertrochanteric Fracture of the Femur in Asian Population

The objective of this study was to assess the rate of screw cut out in elderly patients treated with the dynamic hip screw and the relationship to the Tip Apex Distance (TAD). This is a retrospective radiological evaluat...

Download PDF file
  • EP ID EP306854
  • DOI -
  • Views 106
  • Downloads 0

How To Cite

BB Tan, R Shanmugam, YP Chua, Hossain G, A Saw (2014). A Biomechanical Comparison between Taylor’s Spatial Frame and Ilizarov External Fixator. Malaysian Orthopaedic Journal, 8(2), 35-39. https://europub.co.uk/articles/-A-306854