Open reduction and Internal Fixation of Displaced Proximal Humerus Fractures with AO Stainless Steel T-Plate

Journal Title: Malaysian Orthopaedic Journal - Year 2014, Vol 8, Issue 1

Abstract

Background: Proximal humeral fractures are considered the last unsolved fractures in orthopaedics. The treatment is controversial and various operative modalities have been reported in the literature. The aim of the present study was to evaluate functional outcome and complication rate after open reduction and internal fixation of displaced proximal humerus fractures by proximal humerus AO stainless steel Tplate. Twenty-five (25) patients with displaced proximal humerus fractures treated with proximal humerus T-plate between May 2005 and June 2008 were included in the study. Fractures were classified according to the Neer classification into displaced 2-part, 3-part, and 4-part fractures. Patients were followed-up for a minimum period of two years. Functional evaluation was done according to the Neer scoring system. Scores were compared with other studies in the literature using similar implant. Twenty patients had 2-part fracture, four had 3-part fracture, and one had 4-part fracture. Eighty-eight [88% (n = 22)] patients had good to excellent result, eight [8% (n = 2)] had fair, and four [4% (n = 1)] had poor result. Difference in Neer’s score between 2-part and 3-part fractures was not significant. Complications encountered in this series were screw backout in 8% (n = 2), superficial infection in 12% (n = 3), and avascular necrosis in 4% (n = 1) of cases. We conclude that proximal humerus AO T- plate is a cheap and easily available implant, aspects which are particularly relevant in third world countries like India. It gives reliable fixation for 2-part and 3-part fractures. Its use in more complicated fracture patterns of 4-part fractures is not recommended.

Authors and Affiliations

Hussain S, Gul MA, Dhar DA

Keywords

Related Articles

Lymphatic Filariasis Presenting as a Swelling over the Upper Arm: A Case Report

Filariasis continues to be one of the endemic problems worldwide with 40% of the cases in India. We report a case of lymphatic filariasis in a 32-year old female who presented with a non-tender swelling over left upper a...

Pediatric Orthopedics: A System of Decision-Making

The chapters are uniquely set to cover almost the whole gamut of pediatric orthopedic conditions. The presentation style is crisp and concise, with clear, self explanatory illustrations (mostly drawn by B Joseph himself)...

Post-implantation Deformation of Titanium Rod and Cobalt Chrome Rod in Adolescent Idiopathic Scoliosis

Introduction: Post-implantation rod deformation is anticipated in scoliosis surgery but the difference in rod deformation between titanium and cobalt chrome rod has not been elucidated. This study aims to compare the dif...

Chronic Osteomyelitis Secondary to Human Bite: A Case Report

We report a case of a human bite that was initially inadequately treated and progressed to chronic osteomyelitis, finally resulting in digital amputation. Human bites are seemingly innocuous, but if neglected, may lead t...

Bilateral Traumatic Hip Dislocation in a Child: A Case Report

Traumatic hip dislocation in children is uncommon; when this condition is diagnosed in paediatric patients, it is most frequently seen as a unilateral posterior dislocation and is rarely associated with fracture. We repo...

Download PDF file
  • EP ID EP306652
  • DOI 10.5704/MOJ.1403.011
  • Views 88
  • Downloads 0

How To Cite

Hussain S, Gul MA, Dhar DA (2014). Open reduction and Internal Fixation of Displaced Proximal Humerus Fractures with AO Stainless Steel T-Plate. Malaysian Orthopaedic Journal, 8(1), 8-13. https://europub.co.uk/articles/-A-306652