Open reduction and Internal Fixation of Displaced Proximal Humerus Fractures with AO Stainless Steel T-Plate

Journal Title: Malaysian Orthopaedic Journal - Year 2014, Vol 8, Issue 1

Abstract

Background: Proximal humeral fractures are considered the last unsolved fractures in orthopaedics. The treatment is controversial and various operative modalities have been reported in the literature. The aim of the present study was to evaluate functional outcome and complication rate after open reduction and internal fixation of displaced proximal humerus fractures by proximal humerus AO stainless steel Tplate. Twenty-five (25) patients with displaced proximal humerus fractures treated with proximal humerus T-plate between May 2005 and June 2008 were included in the study. Fractures were classified according to the Neer classification into displaced 2-part, 3-part, and 4-part fractures. Patients were followed-up for a minimum period of two years. Functional evaluation was done according to the Neer scoring system. Scores were compared with other studies in the literature using similar implant. Twenty patients had 2-part fracture, four had 3-part fracture, and one had 4-part fracture. Eighty-eight [88% (n = 22)] patients had good to excellent result, eight [8% (n = 2)] had fair, and four [4% (n = 1)] had poor result. Difference in Neer’s score between 2-part and 3-part fractures was not significant. Complications encountered in this series were screw backout in 8% (n = 2), superficial infection in 12% (n = 3), and avascular necrosis in 4% (n = 1) of cases. We conclude that proximal humerus AO T- plate is a cheap and easily available implant, aspects which are particularly relevant in third world countries like India. It gives reliable fixation for 2-part and 3-part fractures. Its use in more complicated fracture patterns of 4-part fractures is not recommended.

Authors and Affiliations

Hussain S, Gul MA, Dhar DA

Keywords

Related Articles

The Application of Conventional Joint Replacement Templating Techniques to Digital Radiographs: A Novel Technique

Pre-operative templating in arthroplasty is essential in improving surgical precision. More hospitals in Malaysia are employing digital radiographs for this reason. Unfortunately, the software used in arthroplasty templa...

Delayed Presentation of an Unusual Transpharyngeal Penetrating Neck Injury by a Wooden stick: A Case Report

Penetrating neck trauma is a horrifying injury. Patients may present with sudden death, or life threatening injuries such as catastrophic haemorrhage, major vessel injury, injuries to the respiratory or digestive tract,...

A Technique of Distal Clavicle Fracture Fixation Using The Tightrope Procedure

We present here a technique of fracture stabilization using the Tightrope procedure in a patient with a widely displaced Neer type IIB distal clavicle fracture. The Tightrope system, typically used for stabilization of a...

Splinter Removal with the Aid of Ultrasonography: A Case Report

Splinter or foreign body removal from the hand and foot is a common occurrence. Usually only the deep seated, broken or missed splinters are referred to the surgeon for removal. Unless the object is radio-opaque, plain r...

Cinnamon Oil and Chitosan Coating on Orthopaedic Implant Surface for Prevention of Staphylococcus Epidermidis Biofilm Formation

S. Epidermidis is among the most frequently isolated microorganisms found in -infection related to implanted devices and the formation of biofilm will be more resistant compared to the planktonic form. This study was car...

Download PDF file
  • EP ID EP306652
  • DOI 10.5704/MOJ.1403.011
  • Views 94
  • Downloads 0

How To Cite

Hussain S, Gul MA, Dhar DA (2014). Open reduction and Internal Fixation of Displaced Proximal Humerus Fractures with AO Stainless Steel T-Plate. Malaysian Orthopaedic Journal, 8(1), 8-13. https://europub.co.uk/articles/-A-306652