Open reduction and Internal Fixation of Displaced Proximal Humerus Fractures with AO Stainless Steel T-Plate

Journal Title: Malaysian Orthopaedic Journal - Year 2014, Vol 8, Issue 1

Abstract

Background: Proximal humeral fractures are considered the last unsolved fractures in orthopaedics. The treatment is controversial and various operative modalities have been reported in the literature. The aim of the present study was to evaluate functional outcome and complication rate after open reduction and internal fixation of displaced proximal humerus fractures by proximal humerus AO stainless steel Tplate. Twenty-five (25) patients with displaced proximal humerus fractures treated with proximal humerus T-plate between May 2005 and June 2008 were included in the study. Fractures were classified according to the Neer classification into displaced 2-part, 3-part, and 4-part fractures. Patients were followed-up for a minimum period of two years. Functional evaluation was done according to the Neer scoring system. Scores were compared with other studies in the literature using similar implant. Twenty patients had 2-part fracture, four had 3-part fracture, and one had 4-part fracture. Eighty-eight [88% (n = 22)] patients had good to excellent result, eight [8% (n = 2)] had fair, and four [4% (n = 1)] had poor result. Difference in Neer’s score between 2-part and 3-part fractures was not significant. Complications encountered in this series were screw backout in 8% (n = 2), superficial infection in 12% (n = 3), and avascular necrosis in 4% (n = 1) of cases. We conclude that proximal humerus AO T- plate is a cheap and easily available implant, aspects which are particularly relevant in third world countries like India. It gives reliable fixation for 2-part and 3-part fractures. Its use in more complicated fracture patterns of 4-part fractures is not recommended.

Authors and Affiliations

Hussain S, Gul MA, Dhar DA

Keywords

Related Articles

Prevalence and Risk Factors Associated with Low Back Pain Among Health Care Providers in a District Hospital

Study design: A cross-sectional study among health care providers working at one hospital. Objective: To investigate the prevalence, the consequences and the risk factors associated with low back pain (LBP) among hospita...

Cinnamon Oil and Chitosan Coating on Orthopaedic Implant Surface for Prevention of Staphylococcus Epidermidis Biofilm Formation

S. Epidermidis is among the most frequently isolated microorganisms found in -infection related to implanted devices and the formation of biofilm will be more resistant compared to the planktonic form. This study was car...

The Effectiveness of Intravenous Morphine Infusion as Preemptive Analgesia in Preventing Phantom Limb Pain Following Lower Limb Amputation

Phantom limb pain may reduce ambulation and mobility in amputees, resulting in diminished quality of life. We conducted a prospective study to compare the perioperative analgesic use of intravenous morphine infusion in 2...

Understanding Medical Education: Evidence, Theory and Practice Second Edition [2014]

This book has 33 chapters and consists of 5 sections. Part 1 is on the foundations, providing an introduction to medical education, curriculum design, quality improvement, teaching and learning principles. Part 2 discuss...

A Palmar Lipoma with Median and Ulnar Nerve Compressive Symptoms

Although lipoma is common in the upper limbs, it rarely occurs in the palm, and usually does not compress the surrounding structures. Here, we report a patient presenting with compressive neuropathy of the ulna and media...

Download PDF file
  • EP ID EP306652
  • DOI 10.5704/MOJ.1403.011
  • Views 91
  • Downloads 0

How To Cite

Hussain S, Gul MA, Dhar DA (2014). Open reduction and Internal Fixation of Displaced Proximal Humerus Fractures with AO Stainless Steel T-Plate. Malaysian Orthopaedic Journal, 8(1), 8-13. https://europub.co.uk/articles/-A-306652