Cinnamon Oil and Chitosan Coating on Orthopaedic Implant Surface for Prevention of Staphylococcus Epidermidis Biofilm Formation
Journal Title: Malaysian Orthopaedic Journal - Year 2014, Vol 8, Issue 3
Abstract
S. Epidermidis is among the most frequently isolated microorganisms found in -infection related to implanted devices and the formation of biofilm will be more resistant compared to the planktonic form. This study was carried out to determine the effect of coating on stainless steel orthopaedic implants surfaces with cinnamon oil and chitosan as bioadhesive to prevent biofilms formation of S. Epidermidis.The rod shaped stainless steel 316 L orthopaedic implant with 5 mm diameters was coated 2 times using a mixture of cinnamon oil and chitosan 3% and 2% respectively with serial concentration of cinnamon from 0.125% to 2%. The coated implants were then put into tubes that contained bacterial suspension and incubated. Subsequently, the implants were washed with PBS solution followed by MTT soulution and isopropanol acid solution. that related to biofilm formation. The results were expressed in numbers which represents the absorbance level at ELISA readings on 575 nm (A575) wavelength.The stainless steel implant coated with chitosan and cinnamon oil 2% and 1% has lower absorbance level compared with the absorbance level of S.Epidermidis biofilm only. This study showed that mixture of cinnamon oil and chitosan coated on the surface of stainless steel orthopaedic implant has an effect against S.Epidermidis biofilm formation with the minimum cinnamon oil concentration of 1%.
Authors and Affiliations
R Magetsari, P Dewo, BK Saputro, Z Lanodiyu
Dynamic Hip Screw Fixation of Intertrochanteric Fractures of Femur: A Comparison of Outcome With and Without Using Traction Table
Intertrochanteric fracture of the femur is one of the common fractures in the elderly. Dynamic Hip Screw (DHS) fixation is the gold standard for treatment of intertrochanteric femoral fracture. Conventional methods of ac...
Correlation of Foot Bimalleolar Angle and Ultrasonography in Assessing the Severity of Club Foot in Neonates Treated by the Ponseti Method
Introduction: Correlation of Pirani score and foot bimalleolar (FBM) angle has been used in few studies but correlation of FBM angle with ultrasonography has never been evaluated so they are being correlated in assessing...
Haglund Deformity – Surgical Resection by the Lateral Approach
The aim of this study was to analyse the outcome of surgical Haglund deformity is a prominence in the postero superolateral aspect of the calcaneum. Haglund deformity is a in the postero superolateral aspect of the calca...
Aneurysmal Bone Cyst after Femoral Derotational Osteotomy: A Case Report
Aneurysmal bone cysts rather than local aggressive lesions of the bone which may arise in any part of the axial or appendicular skeleton. Although several theories are available in the literature, the pathogenesis is sti...
A Biomechanical Comparison between Taylor’s Spatial Frame and Ilizarov External Fixator
Taylor’s spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanic...