A Biomechanical Comparison of a Novel Expandable Photodynamic Intramedullary System to a Metal Plate and Screw System in Humerus and Femur Osteotomy Models

Journal Title: Orthopedics Research and Traumatology – Open Journal - Year 2016, Vol 1, Issue 1

Abstract

The biomechanical performance of a locking compression plate system was compared to an intramedullary photodynamic bone stabilization system in a femur and humerus osteotomy model. The photodynamic bone stabilization system utilizes an angioplasty-like balloon that is introduced into the intramedullary canal of a fractured bone, filled with monomer that is then polymerized and hardened by visible blue light delivered through an optical fiber. This system has been in clinical use since 2010. Synthetic bones engineered to mimic the biomechanical properties of natural bone were cut to produce a 10 mm defect mid-shaft, and two groups of specimens were stabilized by either the compression plate or intramedullary photodynamic bone stabilization system. For each bone model, one locking compression plate system was used, and three different diameter intramedullary photodynamic bone stabilization implants were used. Experimental groups were tested for stiffness, peak load, yield load, peak displacement and yield displacement when a load was applied. Additional samples per experimental group were tested for long-term dynamic stability by cyclically loading until failure. It was found that in all biomechanical parameters measured, the 17 mm intramedullary photodynamic bone stabilization system exceeded the mechanical strength and durability of the locking compression plate system in the femur osteotomy model. It was found that in all biomechanical parameters measured, the 15 mm intramedullary photodynamic bone stabilization system performed equivalently or exceeded the mechanical strength and durability of the locking compression plate system. This testing combined with long-term clinical use, and in vivo data from a large animal model, suggest that femur fixation by an intramedullary photodynamic bone stabilization system will provide equivalent biomechanical properties to a locking compression plate once implanted.

Authors and Affiliations

Benjamin R. Johnston

Keywords

Related Articles

Isokinetic Muscle Strength in Recreational Athletes with Partial ACL Lesions Treated with Surgical Reconstruction

Background: Surgery that spares the intact portion of the ACL seems to be more favorable. This surgical technique has a positive effect on joint stability, joint position sense and functional scores in patients with part...

Complications in the Combined and Consecutive Use of External and Internal Fixation of the Femur with Reference to Use of the Extracortical Clamp Device

Aim The Extracortical Clamp Device (ECD) is a novel external fixation component which unlike conventional implants does not perforate long bone cortices. Therefore, it simplifies methods of combined and consecutive inter...

Balloon Kyphoplasty: Cement Augmentation in Acute Osteoporotic Thoraco-Lumbar Fractures

Background Several techniques have been developed for simpler and safer procedures during the last 2 decades. Techniques of vertebral body augmentation have been developed in an effort to treat these refractory cases. Th...

Are Post-Operative Drains Beneficial in Total and Reverse Total Shoulder Arthroplasty?

Background: Total shoulder arthroplasty (TSA) and reverse total shoulder arthroplasty (RTSA) are effective treatments for glenohumeral arthritis and rotator cuff arthropathy. Purpose: To determine if the use of a post op...

Changing Ethics and the Hippocrates Oath

When I graduated in 1973 and registered with the Rajasthan state branch of the Medical Council of India, I was given a copy of the Hippocratic Oath. That it is no longer the practice speaks volumes for what it is worth....

Download PDF file
  • EP ID EP552514
  • DOI 10.17140/ORTOJ-1-102
  • Views 116
  • Downloads 0

How To Cite

Benjamin R. Johnston (2016). A Biomechanical Comparison of a Novel Expandable Photodynamic Intramedullary System to a Metal Plate and Screw System in Humerus and Femur Osteotomy Models. Orthopedics Research and Traumatology – Open Journal, 1(1), 5-13. https://europub.co.uk/articles/-A-552514