A clinical study of the Safe use of Tourniquet – A prospective observational study

Journal Title: Indian Journal of Orthopaedics Surgery - Year 2017, Vol 3, Issue 2

Abstract

Introduction: This study was undertaken to evaluate LOP (lowest occlusion pressure) is superior to the other ways of usage of Pneumatic Tourniquets in Orthopaedics surgery i.e. Fixed and Systolic BP variant. Materials and Method: 120 cases of both upper and lower limbs operated from period September 2013 to October 2015 are randomly included in the study after full filling the inclusion and exclusion criteria and managed using Fixed, Systolic BP and LOP, each of the groups included 40 cases and results were analysed according to final outcome using Ishii et al. grading, VAS Score criteria. Results: In our study 120 cases managed by LOP has a better result when compared to fixed variant and Systolic BP variant in terms of less pressure needed to keep tourniquet, good operative field, pain score (VAS) at tourniquet application region and skin injury(reddening). Bloodless field was excellent in 33 patients {[14 (35%) in LOP, 9(22.5%) in Systemic and 10 (25%) in Fixed Tourniquet variant. Among 120 patients, 11 (27.5%), 35 (87.5%) and 40 (100%) patients had experienced Skin abrasions/ Flaring were observed in the patient who underwent LOP, systemic and Fixed Tourniquet respectively. But no complications like compartment syndrome, deep vein disorder, paresis, nerve injury has occurred before and after surgery. Conclusion: LOP is superior to all other ways of Tourniquet in terms of less pressure needed for elevating tourniquet, Good operative (bloodless) field, no skin abrasions.

Authors and Affiliations

Ravikiran H G, Adarsh T, Gowrahar . , Ravi Shankar, Tushar Pimpale

Keywords

Related Articles

Tip apex distance - Is it enough to predict implant failure in trochanteric fractures

Introduction: The tip-apex distance (TAD) is the sum of the distances from the tip of lag screw to apex of the femoral head on both AP and lateral radiographs. A TAD of greater than 25 mm is considered to be an accurate...

Complex proximal tibia fracture dislocations managed by Ilizaorov fixator- A case series with review of literature

Background: Bicondylartibial fractures are serious injuries and are difficult to manage even for the most experienced trauma surgeons. The soft tissue around proximal tibia demonstrates poor healing response following di...

Evaluation of Implant Failure in Long Bones Fractures – A Retrospective Study

Background: Variety of implant design and quality are available and being used by orthopaedic surgeon to restore anatomy and enhance healing process of fractured bone. At times implants fail to achieve desired out come i...

Dynamic HIP screw vs proximal trochanteric contoured plate in proximal end fractures of femur

Purpose: To compare the outcome in patients who underwent surgery for proximal end femur fracture, intertrochanteric and Subtrochanteric, using dynamic hip screw vs proximal femoral locking plate. Methods: 11 men and 19...

An analysis of functional outcome following tendon augmentation surgeries in patients presenting with steroid-induced tendo achilles rupture and spontaneous tendo achilles ruptures

Introduction Achilles tendon is the strongest tendon in the body paradoxically is also the commonest one to undergo rupture Corticosteroids are one of the most commonly used drugs in tendon disorders also it is blamed fo...

Download PDF file
  • EP ID EP293919
  • DOI 10.18231/2395-1362.2017.0038
  • Views 116
  • Downloads 0

How To Cite

Ravikiran H G, Adarsh T, Gowrahar . , Ravi Shankar, Tushar Pimpale (2017). A clinical study of the Safe use of Tourniquet – A prospective observational study. Indian Journal of Orthopaedics Surgery, 3(2), 193-196. https://europub.co.uk/articles/-A-293919