A Comparative Study Between Titanium Mini Plates And 3 Dimensional Titanium Plates With Locking Screws Using Bite Force Evaluation Of Anterior Mandibular Fractures

Journal Title: INTERNATIONAL JOURNAL OF CURRENT RESEARCH - Year 2018, Vol 10, Issue 9

Abstract

Purpose: The purpose of this study is to compare the efficacy, stability and rigidity of three-dimensional (3D) titanium plate with locking screws and standard titanium miniplates for mandibular anterior fractures treatment using bite force measurements. Patients and Methods: A prospective randomized controlled clinical study for the treatment of mandibular fractures was conducted as a multicentre study at Indira Gandhi Institute of Dental Science, Puducherry, India, in the time period of 2012–2014. Twenty patients were randomly divided into two equal groups. Ten patients in group I underwent osteosynthesis with standard titanium miniplates and ten patients in group II underwent osteosynthesis with 3D titanium locking miniplates. The surgical technique was standardized. The clinical parameter assessed was the bite force measurement in relation to the incisor, right molar, and left molar regions. Follow up was done at seventh day, third week, sixth week and third month. Results: In this study, a statistically significant change was present between the change in bite force in each follow up in groups I and II. The difference in the incisor, right molar and left molar bite force was significantly higher for group II compared to group I. There were no statistically significant changes in the clinical parameters such as infection, operating time and occlusion. Conclusion: 3D titanium miniplates with locking screws are better in fracture stabilization for anterior mandibular fractures when compared with titanium miniplates. Other postoperative findings show similar changes in both groups.

Authors and Affiliations

Denny George, Suresh, V. , Sathyanarayanan, R. , Rajkumar, R. and Harish, V.

Keywords

Related Articles

A REVIEW ON THE MALE JUVENILE CHRONIC PELVIC PAIN SYNDROME

There are many studies dealing with CPPS (chronic pelvic pain syndrome) which is very common urologic disorder but the reports about juvenile CPPS is rare. Urology outpatient visits of juvenile CPPS patients is very low...

Dental link of lord ram existence

Aim: To prove the link of Aryans and Caucasians through dentistry and to prove the hypothesis of lord Ram actual existence. Introduction: There are documented facts that there was advent of Aryans in India. There are ant...

Variations in morphology of cerebral hemispheres and their clinical implications with special reference to polygyria

Polygyria is a developmental anomaly of the brain characterized by development of numerous small gyri. It is a neuronal migration cortical organization disorder which is often sporadic or genetic but is also seen seconda...

Prevalence of psychiatric morbidity in hiv positive patients in a tertiary hospital in Nigeria

Background: Human immunodeficiency virus (HIV) is a chronic multi-systemic disorder with associated psychiatric co-morbidity of significant public health importance. Aim: The study focused on investigating the prevalence...

Feeding appliance fabrication for a colpocephaly associated with cleft palate child: a rare case report

Colpocephaly is an abnormal enlargement of occipital horn of lateral ventricle associated with several abnormalities. Various etiologies have been reported including intrauterine/ perinatal injuries, genetic disorder and...

Download PDF file
  • EP ID EP403423
  • DOI -
  • Views 89
  • Downloads 0

How To Cite

Denny George, Suresh, V. , Sathyanarayanan, R. , Rajkumar, R. and Harish, V. (2018). A Comparative Study Between Titanium Mini Plates And 3 Dimensional Titanium Plates With Locking Screws Using Bite Force Evaluation Of Anterior Mandibular Fractures. INTERNATIONAL JOURNAL OF CURRENT RESEARCH, 10(9), 73279-73285. https://europub.co.uk/articles/-A-403423