A Comparative Study Between Titanium Mini Plates And 3 Dimensional Titanium Plates With Locking Screws Using Bite Force Evaluation Of Anterior Mandibular Fractures

Journal Title: INTERNATIONAL JOURNAL OF CURRENT RESEARCH - Year 2018, Vol 10, Issue 9

Abstract

Purpose: The purpose of this study is to compare the efficacy, stability and rigidity of three-dimensional (3D) titanium plate with locking screws and standard titanium miniplates for mandibular anterior fractures treatment using bite force measurements. Patients and Methods: A prospective randomized controlled clinical study for the treatment of mandibular fractures was conducted as a multicentre study at Indira Gandhi Institute of Dental Science, Puducherry, India, in the time period of 2012–2014. Twenty patients were randomly divided into two equal groups. Ten patients in group I underwent osteosynthesis with standard titanium miniplates and ten patients in group II underwent osteosynthesis with 3D titanium locking miniplates. The surgical technique was standardized. The clinical parameter assessed was the bite force measurement in relation to the incisor, right molar, and left molar regions. Follow up was done at seventh day, third week, sixth week and third month. Results: In this study, a statistically significant change was present between the change in bite force in each follow up in groups I and II. The difference in the incisor, right molar and left molar bite force was significantly higher for group II compared to group I. There were no statistically significant changes in the clinical parameters such as infection, operating time and occlusion. Conclusion: 3D titanium miniplates with locking screws are better in fracture stabilization for anterior mandibular fractures when compared with titanium miniplates. Other postoperative findings show similar changes in both groups.

Authors and Affiliations

Denny George, Suresh, V. , Sathyanarayanan, R. , Rajkumar, R. and Harish, V.

Keywords

Related Articles

Assessment and Categorisation of abnormal uterine bleeding according to palm-coein classification

Background: Abnormal uterine bleeding (AUB) is a common cause for concern among reproductive women, sometimes debilitating, for which patients seek advice in gynecology outpatient department. The aim of the study was: 1...

Bradycardia following propofol induction

Propofol has been described as a potent hypnotic drug producing anaesthesia within one arm-brain circulation time, possessing a rapid recovery time and causing minimal postoperative sequelae. It has also been associated...

A Study On Hiv-Tuberculosis Co-Infection And Correlation With Cd4+ T Lymphocyte Le-Vels At Agartala Government Medical College

Background: Human Immunodeficiency Virus (HIV) and Tuberculosis (TB) co-infection is a lamentable medical phenomenon and CD4 count among them is a surrogate marker of their immune status.Objectives: 1. To study the epide...

Modified Coronally Advanced Flap (Zucchellli Technique): A Case Series

Background: Desire for improved aesthetics and the consequent need for cosmetic dentistry have increased tremendously in recent times making aesthetic procedures an integral part of periodontal treatment. The treatment o...

Comparison of staining of mitotic figures by h and e and crystal violet stains in odontogenic tumors with aggressive behaviour- a preliminary study

Background: Some odontogenic tumors are clinically benign but they are locally aggressive and recur. Therefore such lesions should be completely evaluated for their mitotic potential. Routine staining procedures often po...

Download PDF file
  • EP ID EP403423
  • DOI -
  • Views 118
  • Downloads 0

How To Cite

Denny George, Suresh, V. , Sathyanarayanan, R. , Rajkumar, R. and Harish, V. (2018). A Comparative Study Between Titanium Mini Plates And 3 Dimensional Titanium Plates With Locking Screws Using Bite Force Evaluation Of Anterior Mandibular Fractures. INTERNATIONAL JOURNAL OF CURRENT RESEARCH, 10(9), 73279-73285. https://europub.co.uk/articles/-A-403423