A comparative study of blood glucose level measurement between glucometer and semi autoanalyser
Journal Title: International Journal of Clinical Biochemistry and Research - Year 2018, Vol 5, Issue 3
Abstract
Introduction There is a direct relationship between glycemic control and risk of systemic complications leading to high morbidity and mortality in diabetes3 Estimation of blood glucose is the main investigation for the diagnosis and management of diabetes mellitus and also for monitoring emergency complications of DM Glucometers are used for monitoring blood glucose levels in most of the hospitals There is a need for establishing the reliability of results of glucometer as they also have limitations6 Our study is undertaken to compare the glucose levels in capillary whole blood by glucometer and glucose levels in venous plasma samples by semi autoanalyserMaterials and Methods Study was conducted in the department of Biochemistry Osmania General Hospital 50 Subjects both male and female in the age group of 25 to 65yrs attending out patient department of Medicine at Osmania General Hospital were included in the study Capillary blood glucose is measured with a glucometer and venous plasma sample glucose is measured with a semi autoanalyser Statistical analysis is done by mean comparison and student t testResults When the two means are compared there is increase in the blood glucose levels measured by using a glucometer 117763901 when compared to venous blood samples levels measured by using a semi autoanalyzer 108783905 but there is no statistical significance P 005 Results showed a variation of 2 to 15 in individual subjects between the blood glucose levels by two methodsConclusion Mean glucose levels in capillary blood sample estimated by glucometer is higher than the mean glucose levels in venous plasma samples estimated by semi autoanalyser but there is no statistical significance Hence glucometer can be used at bedside as a better alternative for out patient department diagnosis and in emergency situationsKeywords Glucometer Semi auto analyser Blood glucose
Authors and Affiliations
N. V. Lakshmi, P. Kiranmai
Occupational lead exposure and its effect on human liver functions
Introduction: A Comparative study of persons working in lead based industries and non-lead based industries were undertaken to evaluate the effect of lead on liver function tests. This study was done to evaluate the ill...
Prevalence of Haemoglobinopathies in Punjabi population
Background: The prevalence of thalassemias and various hemoglobinopathies are a major public health problem in Punjabi population. These cases are mainly overlooked and thus only treated as a part of anaemia. Thus it is...
Study of oxidative stress in women with preeclampsia
Introduction: Root cause of preeclampsia is placental ischemia due to impaired trophoblastic invasion in uterine spiral arterioles. Ischemic placenta liberates various inflammatory mediators. Inflammation is associated w...
Effect of thyroid hormones on serum calcium and phosphorous
Introduction Calcium and phosphorous are the two important minerals whose abnormalities are most ignored in the developing countries The impact of calcium abnormalities ranges from abdominal pain muscle spasms psychiatri...
A comparative study of serum estrogen and lipid profile in pre-menopausal and post-menopausal women as atherosclerotic risk factors
Objectives: Menopause is the permanent cessation of menstruation; since cardiovascular disease is the leading cause of death among post-menopausal women, which may be due to lower level of estrogen. The present study was...