A Comparative Study to Assess the Predictability of Different IOL Power Calculation Formulas in Eyes of Short and Long Axial Length
Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 1
Abstract
Introduction: Accurate Intraocular Lens (IOL) power calculation in cataract surgery is very important for providing postoperative precise vision. Selection of most appropriate formula is difficult in high myopic and hypermetropic patients. Aim: To investigate the predictability of different IOL (Intra Ocular Lens) power calculation formulae in eyes with short and long Axial Length (AL) and to find out most accurate IOL power calculation formula in both groups. Materials and Methods: A prospective study was conducted on 80 consecutive patients who underwent phacoemulsification with monofocal IOL implantation after obtaining an informed and written consent. Preoperative keratometry was done by IOL Master. Axial length and anterior chamber depth was measured using A-scan machine ECHORULE 2 (BIOMEDIX). Patients were divided into two groups based on AL. (40 in each group). Group A with AL<22 mm and Group B with AL>24.5 mm. The IOL power calculation in each group was done by Haigis, Hoffer Q, Holladay-I, SRK/T formulae using the software of ECHORULE 2. The actual postoperative Spherical Equivalent (SE), Estimation error (E) and Absolute Error (AE) were calculated at one and half months and were used in data analysis. The predictive accuracy of each formula in each group was analyzed by comparing the Absolute Error (AE). The Kruskal Wallis test was used to compare differences in the (AE) of the formulae. A statistically significant difference was defined as p-value<0.05. Results: In Group A, Hoffer Q, Holladay 1 and SRK/T formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm and accuracy of these three formulae was significantly higher than Haigis formula. Whereas in Group B, Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL more than 24.5 mm. Conclusion: Hoffer Q, Holladay 1 and SRK/T formulae were showing significantly higher accuracy than Haigis formula in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm. In eyes with AL more than 24.5 mm Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate.
Authors and Affiliations
Dharmil Doshi, purvi limdi, nilesh parekh, neepa gohil
Comparative Evaluation of Procalcitonin and Interleukin-6 as Diagnostic and Prognostic Biomarkers for Sepsis
ABSTRACT Introduction: Diagnosis of sepsis is based on host’s systemic inflammatory response to infection including life-threatening organ dysfunction. Various biomarkers are available for diagnosis and prognostication...
Extramedullary Haematopoiesis Presenting as an Adrenal Mass
Images in Medicine
Morphologic Spectrum of Duodenal Biopsies in Malabsorption: A Study from Southern India
Introduction: Duodenal endoscopic biopsy is a common investigation for various non-neoplastic conditions. Malabsorption is a common indication for duodenal biopsy in our setting. Aim: Our study was undertaken to study th...
Homozygous Protein C Deficiency in a Premature Infant- A Case Report
Homozygous protein C deficiency is a rare autosomal recessive inherited disorder manifesting as neonatal purpura fulminans. A two-day-old male baby delivered at 31 weeks developed purpuric lesions over the left medial ma...
Post Stroke Psychosis Following Lesions in Basal Ganglion
Stroke is the second most common cause of death and fourth leading cause of disability worldwide. Post stroke behavioural manifestations are often not recognized, undiagnosed and hence remain untreated. They may even suf...