A high throughput chemiluminescence method based on molecularly imprinted sol-gel films for determination of sibutramine

Journal Title: Advanced Materials Letters - Year 2010, Vol 1, Issue 2

Abstract

A novel and high throughput chemiluminescence (CL) method for determination of sibutramine was originally developed based on potassium permanganate-hydrochloric acid-(tween-80) CL system. Molecularly imprinted sol-gel film (MIF) was synthesized and used as selective material to improve the selectivity of CL. In the proposed procedure, sibutramine molecule as adsorbed into the MIF, and then potassium permanganate, hydrochloric acid and tween-80 were added in wells of a 96-well plate, Based on which, sibutramine was oxidized and CL was produced and detected by a photomultiplier tube (PMT). The CL intensity was correlated linear with the concentration of sibutramine over the range of 5.0 × 10[sup]-8[/sup]-1.0 × 10[sup]-6[/sup] g mL[sup]-1[/sup] and the detection limit was 1.8 × 10[sup]-8 [/sup]g mL[sup]-1[/sup]. The relative standard deviation (RSD) was 3.1% for determination of 1.0 × 10[sup]-7[/sup] g mL[sup]-1[/sup] sibutramine (n = 11). The fabricated molecularly imprinted sol-gel film possessed good selectivity and could be regenerated. This method was successfully applied to the determination of sibutramine in weight-reducing tonic.

Authors and Affiliations

Fuwei Wan, Jinghua Yu, Shenguang Ge, Mei Yan, Kexiao Yu, Meng Zhang

Keywords

Related Articles

Bio- nanomaterials for versatile bio- molecules detection technology

Over the past few years, bionanomaterial research has emerged as a new exciting field and the importance of DNA, RNA and peptides in designing bionanomaterials for the fundamental development in biotechnology and nanomat...

A high throughput chemiluminescence method based on molecularly imprinted sol-gel films for determination of sibutramine

A novel and high throughput chemiluminescence (CL) method for determination of sibutramine was originally developed based on potassium permanganate-hydrochloric acid-(tween-80) CL system. Molecularly imprinted sol-gel fi...

Deoxyribonucleic acid imprinted biosensor technology

In recent years, molecularly imprinted polymers (MIPs) have attracted much attention due to many of its potential applications including sensors, separation, catalysis, drug delivery and waste management. To prepare MIPs...

SHG relaxation behaviour in m-nitroaniline doped PMMA guest-host system

 In present work, we have reported the second harmonic generation (SHG) property on the Guest-Host system based on optical grade poly(methyl methacrylate) (PMMA) and m-Nitroaniline (m-NA) for their use in optoelectr...

Download PDF file
  • EP ID EP84941
  • DOI 10.5185/amlett.2010.7138
  • Views 170
  • Downloads 0

How To Cite

Fuwei Wan, Jinghua Yu, Shenguang Ge, Mei Yan, Kexiao Yu, Meng Zhang (2010). A high throughput chemiluminescence method based on molecularly imprinted sol-gel films for determination of sibutramine. Advanced Materials Letters, 1(2), 164-169. https://europub.co.uk/articles/-A-84941