A New Approach for Enhancing the Quality of Medical Computerized Tomography Images

Abstract

Computerized tomography (CT) images contribute immensely to medical research and diagnosis. However, due to degradative factors such as noise, low contrast, and blurring, CT images tend to be a degraded representation of the actual body or part under investigation. To reduce the risk of imprecise diagnosis associated with poor-quality CT images, this paper presents a new technique designed to enhance the quality of medical CT images. The main objective is to improve the appearance of CT images in order to obtain better visual interpretation and analysis, which is expected to ease the diagnosis process. The proposed technique involves applying a median filter to remove noise from the CT images and then using a Laplacian filter to enhance the edges and the contrast in the images. Also, as CT images suffer from low contrast, a Contrast Limited Adaptive Histogram Equalization transform is also applied to solve this problem. The main strength of this transform is its modest computational requirements, ease of application, and excellent results for most images. According to a subjective assessment by a group of radiologists, the proposed technique resulted in excellent enhancement, including that of the contrast and the edges of medical CT images. From a medical perspective, the proposed technique was able to clarify the arteries, tissues, and lung nodules in the CT images. In addition, blurred nodules in chest CT images were enhanced effectively. Therefore the proposed technique can help radiologists to better detect lung nodules and can also assist in diagnosing the presence of tumours and in the detection of abnormal growths.

Authors and Affiliations

Mutaz Al-Frejat, Mohammad HjoujBtoush

Keywords

Related Articles

Comparatative Analysis of Energy Detection Spectrum Sensing of Cognitive Radio Under Wireless Environment Using SEAMCAT

In the recent years, the Cognitive Radio technology imposed itself as a good solution to enhance the utilization of unused spectrum and globalized the radio environment for different band users that utilize or require di...

Model Study and Fault Detection for the Railway System

The wheel-rail-sleepers system is simulated as a series of moving point loads on an Euler–Bernoulli beam resting on a visco-elastic half space. This paper concentrates on the rail-sleepers interaction system (railway sys...

OPTIMIZING THE USE OF AN SPI FLASH PROM IN MICROBLAZE-BASED EMBEDDED SYSTEMS

This paper aims to simplify FPGA designs that incorporate Embedded Software Systems using a soft core Processor. It describes a simple solution to reduce the need of multiple non-volatile memory devices by using one SPI...

Software Defined Security Service Provisioning Framework for Internet of Things

Programmable management framework have paved the way for managing devices in the network. Lately, emerging paradigm of Software Defined Networking (SDN) have rev-olutionized programmable networks. Designers of networking...

Optimization of a Three-Phase Tetrahedral High Voltage Transformer used in the Power Supply of Microwave

This article deals with the optimization of a three-phase tetrahedral-type high voltage transformer, sized to supply three voltage-doubling cells and three magnetrons per phase. The optimization method used is based on a...