A New Quantification Method of Bacterial Adherence on Implant Surfaces in an Implant Associated Infection Rat Model

Journal Title: Journal of Medical Diagnostic Methods - Year 2018, Vol 7, Issue 2

Abstract

Objective: Implant infections in elective orthopedic surgery are still a clinically relevant problem with devastating consequences for the patient. Thereof results a great need for new strategies to prevent implant infections. Functionalization of implant surfaces to reduce the microbial adherence show great potential in vitro, but have to be tested in suitable models in vivo. Proper evaluation methods of the bacterial load on the implant surface are important for their evaluation. Up to now, the simultaneous assessment of the quantity and morphology of the bacterial infection in vivo was not performed. Methods: Cubic Ti90/Al6/V4-rods were inserted in the tibia of Lewis rats and infected with Staphylococcus aureus strain 36/07 in different concentrations. After 21 days, explanted implants were stained for living and dead cells. The bacterial surface colonization was analyzed by confocal microscopy and assessed semi quantitatively via two different approaches (spot method and volume method) using the software Imaris® × 64. Furthermore the bacterial morphology was evaluated. The results were compared to radiographic and histological changes. Results: The new semi quantitative CLSM evaluation to assess the bacterial biomass on implant surfaces was successfully implemented. Both methods gave equivalent results. The results of the morphologic assessment of the bacterial colonization were similar to those of the quantification. A tendency towards increasing bacterial biomass and biofilm formation on the implant surface was observed with decreasing infection concentrations. In contrast, histologic and radiographic assessment as well as the relative tibial bone weight revealed more severe changes for higher inoculation concentrations. Conclusion: In combination with the morphological assessment of the bacterial appearance this CLSM based evaluation is a suitable tool to assess the bacterial load on the implant surface. Combined with radiographical and histological evaluation of bone alterations, this model is appropriate for the evaluation of new implant surfaces.

Authors and Affiliations

Schröder ML, Angrisani N, Hegermann J, Windhagen H, Callie ß T, Reifenrath J

Keywords

Related Articles

Diagnostic Accuracy of 3T MR in Staging of Uterine Cervical Carcinoma

Objective: We aimed to evaluate the diagnostic accuracy of 3T MRI sequences for staging of uterine cervical carcinoma (CC).Methods: We examined 22 cases of CC by a 3T MRI with T2W single shot turbo spin echo, diffusion w...

Determination of Calibration Cycles Using X-ray Tube Output, Workload and Use Factor for Diagnostic X-rays

The stipulated standard time according to annual inspection done under the Health Facility Act 2008 is once per year however, due to varying workloads, use factor, and tube age the calibration cycles can be adjusted. Sig...

Cholangiocarcinoma: A Single-center Western Experience

Background: The purpose of this study was to summarize the surgical management and to evaluate survival rate and clinical outcome of cholangiocarcinoma, in patients hospitalized in our Unit of Oncology and General Surger...

Enhancing Quality Management through Effective Quality Assurance in Jamaican Radiology Centres

Objectives: To conduct a quality control assessment among Jamaican radiology facilities in a bid to create a consistent platform that can be employed as a standard for baseline radiation measurements and evaluation. Meth...

The Value of 99mTc-EHIDA Hepatobiliary Scintigraphy with Different Liver/Kidney Ratio in the Distinguish of Infant Persistent Jaundice

Objective: To evaluate the value of 99mTc-EHIDA hepatobiliary scintigraphy with different Liver/Kidney ratio (LKR) in the distinguish of infant persistent jaundice. Methods: A total of 128 patients with infant persistent...

Download PDF file
  • EP ID EP580894
  • DOI 10.4172/2168-9784.1000271
  • Views 91
  • Downloads 0

How To Cite

Schröder ML, Angrisani N, Hegermann J, Windhagen H, Callie ß T, Reifenrath J (2018). A New Quantification Method of Bacterial Adherence on Implant Surfaces in an Implant Associated Infection Rat Model. Journal of Medical Diagnostic Methods, 7(2), 1-9. https://europub.co.uk/articles/-A-580894