Determination of Calibration Cycles Using X-ray Tube Output, Workload and Use Factor for Diagnostic X-rays

Journal Title: Journal of Medical Diagnostic Methods - Year 2018, Vol 7, Issue 2

Abstract

The stipulated standard time according to annual inspection done under the Health Facility Act 2008 is once per year however, due to varying workloads, use factor, and tube age the calibration cycles can be adjusted. Significance of this work includes determining the optimal calibration time of diagnostic X-ray tubes, resulting in promotion of new knowledge and influencing policies on the need for timely calibrations, additionally it may be used as a marker for urgent calibration in high workload facilities via diagnostic reference per unit to establish an institutional local standard. Parameters involved in this research are X-ray tube output (mGy/mAs), workload (mAmin/ week), use factor and fluence (mGy/cm2). Comparative studies were done at two local hospitals in Guyana namely Georgetown Public Hospital Corporation (GPHC) and Linden Hospital Corporation (LHC). Barium meals (B.M) and intravenous pyelograms (IVP) were measured at Georgetown Public Hospital Corporation. The RaySafe X2 was placed in the path of the X-ray beam at different settings of peak kilovoltage and millamperage- second and the radiation quantities were displayed on the base unit. This research investigated the effect of variation factor on the calibration of the static radiography on a fluoroscopy unit. Factors measured included kerma, tube output, fluence and age of tube output and workload. The differences obtained were significant in the cases of the elevated R/F sensor at 60 cm and at table top of 115 cm and varying peak kilovoltages and milliamperage. The difference in tube output could be attributed to anode surface damage (pitting), age of the tube, filtration, and collimation. A lower workload requires less calibration. In conclusion facilities with a workload of approximately 50 patients do not require more frequent calibration.

Authors and Affiliations

Jermain Exeter, Petal Surujpaul

Keywords

Related Articles

Muscle Volume Measurement for Intensive Care Unit Acquired weakness using Computed Tomography: A Pilot Study

Muscle volume measurement is important for ICUAW evaluation, which has been done using ultrasound and manual muscle testing. We compared the reliability of CT and other methods for muscle volume measurement. This observa...

Determination of Calibration Cycles Using X-ray Tube Output, Workload and Use Factor for Diagnostic X-rays

The stipulated standard time according to annual inspection done under the Health Facility Act 2008 is once per year however, due to varying workloads, use factor, and tube age the calibration cycles can be adjusted. Sig...

The Value of 99mTc-EHIDA Hepatobiliary Scintigraphy with Different Liver/Kidney Ratio in the Distinguish of Infant Persistent Jaundice

Objective: To evaluate the value of 99mTc-EHIDA hepatobiliary scintigraphy with different Liver/Kidney ratio (LKR) in the distinguish of infant persistent jaundice. Methods: A total of 128 patients with infant persistent...

Effect of a Course of Biostatistics in an Integrated Curriculum

Aim: Lack of knowledge for biostatistics adversely affect the skills required for a competent physician. However, literature is deficient to show whether medical students learn it and course of biostatistics is effective...

Diagnostic Accuracy of 3T MR in Staging of Uterine Cervical Carcinoma

Objective: We aimed to evaluate the diagnostic accuracy of 3T MRI sequences for staging of uterine cervical carcinoma (CC).Methods: We examined 22 cases of CC by a 3T MRI with T2W single shot turbo spin echo, diffusion w...

Download PDF file
  • EP ID EP580884
  • DOI 10.4172/2168-9784.1000269
  • Views 76
  • Downloads 0

How To Cite

Jermain Exeter, Petal Surujpaul (2018). Determination of Calibration Cycles Using X-ray Tube Output, Workload and Use Factor for Diagnostic X-rays. Journal of Medical Diagnostic Methods, 7(2), 1-8. https://europub.co.uk/articles/-A-580884