Muscle Volume Measurement for Intensive Care Unit Acquired weakness using Computed Tomography: A Pilot Study
Journal Title: Journal of Medical Diagnostic Methods - Year 2018, Vol 7, Issue 1
Abstract
Muscle volume measurement is important for ICUAW evaluation, which has been done using ultrasound and manual muscle testing. We compared the reliability of CT and other methods for muscle volume measurement. This observational study assessed 7 patients 40 years old or older who had been admitted to our ICU. Based on a prespecified CT protocol, muscle volume was evaluated on admission day and at 10-14 days after admission. Results show that the femoral muscle volume decreased significantly by up to 20%. The ICC between two raters was 0.97. Psoas muscle volume decline did not correlate with the femoral muscle decline. Femoral muscle volume evaluation was reliable and objective. This method is useful to quantify the ICUAW severity. Our pilot study based on CT femoral muscle volume evaluation will facilitate further studies to prevent ICUAW. Results show that CT using femoral muscle volume measurement is a reliable means of ICUAW evaluation.
Authors and Affiliations
Tomohiro Sonoo, Hiromu Naraba, Atsushi Kibata, Kazutaka Fukushima, Hiroaki Daidoji, Hideki Hashimoto, Kensuke Nakamura
Comparing a Polymerase Chain Reaction (PCR) Based Analysis for Gender Determination in Early Stage of Pregnancy versus Sonography
Objective: The aim of this study was to evaluate two genes as candidates for fetal sex determination by PCR from blood samples during the first trimester of pregnancy and then contrast the results with the sonography in...
Establishment of Computed Tomography Diagnostic Reference Levels in Tobruk
ntroduction: CT examinations are the cause of 40% of the collective dose resulting from medical exposure inthe UK. The use of CT in the UK and worldwide is still increasing, so it is likely that the contribution to colle...
Cholangiocarcinoma: A Single-center Western Experience
Background: The purpose of this study was to summarize the surgical management and to evaluate survival rate and clinical outcome of cholangiocarcinoma, in patients hospitalized in our Unit of Oncology and General Surger...
Determination of Calibration Cycles Using X-ray Tube Output, Workload and Use Factor for Diagnostic X-rays
The stipulated standard time according to annual inspection done under the Health Facility Act 2008 is once per year however, due to varying workloads, use factor, and tube age the calibration cycles can be adjusted. Sig...
Enhancing Quality Management through Effective Quality Assurance in Jamaican Radiology Centres
Objectives: To conduct a quality control assessment among Jamaican radiology facilities in a bid to create a consistent platform that can be employed as a standard for baseline radiation measurements and evaluation. Meth...