Assessment of Personnel Dosimetry in Radiotherapy at Cancer Institute Guyana

Journal Title: Journal of Medical Diagnostic Methods - Year 2018, Vol 7, Issue 1

Abstract

The only radiotherapy facility in Guyana, located at Cancer Institute Guyana (CIG) has a linear accelerator (LINAC), potential to produce photons of 6 Megavolts and 6 electrons energies of 5,7,8,10,12 and 14 MeV. This research aims to evaluate the levels of ionizing radiation retrospectively received by the OEP in the radiotherapy facility at CIG for 5 consecutive years from 2010 to 2014 inclusively and to relate the findings to the national and international dose limits of 20 mSv/year, for both safety and regulatory purposes to avoid and/or reduce biological effects. The Occupationally Exposed Personnel (OEP) are routinely monitored by the quarterly genesis Ultra TD dosimeter authorized by Sierra Radiation Dosimeter Service. Even though the results were well below the National and International dose limit, the results produced a variation of more than 2.1 mSv with a minimum mean annual dose of 0.264 mSv and a maximum mean annual dose of 2.353 mSv. Each OEP dose readings throughout the years was significantly below 5 mSv/year. These results allows the researcher to conclude even though the dose is well below 20 mSv, the need for optimization still applies. Background radiation, cannot be removed completely, but continuous monitoring should be done to help keep allows for radiation dose As Low As Reasonable Achievable (ALARA).

Authors and Affiliations

Basmattie Sawh, Deivis Errada, Petal Surujpaul

Keywords

Related Articles

Assessment of Personnel Dosimetry in Radiotherapy at Cancer Institute Guyana

The only radiotherapy facility in Guyana, located at Cancer Institute Guyana (CIG) has a linear accelerator (LINAC), potential to produce photons of 6 Megavolts and 6 electrons energies of 5,7,8,10,12 and 14 MeV. This re...

An Evaluation of the Effectiveness of the Structural Radiation Shielding Barriers of a Radiation Therapy Facility: Cancer Institute of Guyana

This project thoroughly investigates the integrity of the structural radiation shielding barriers of the radiation therapy facility of Cancer Institute of Guyana which houses a Linear Accelerator (LINAC) of 6 MV. The LIN...

Cholangiocarcinoma: A Single-center Western Experience

Background: The purpose of this study was to summarize the surgical management and to evaluate survival rate and clinical outcome of cholangiocarcinoma, in patients hospitalized in our Unit of Oncology and General Surger...

Determination of Calibration Cycles Using X-ray Tube Output, Workload and Use Factor for Diagnostic X-rays

The stipulated standard time according to annual inspection done under the Health Facility Act 2008 is once per year however, due to varying workloads, use factor, and tube age the calibration cycles can be adjusted. Sig...

Value of Alberta Stroke Program early Computed Tomography Score (ASPECTS) in the Evaluation of Middle Cerebral Artery Acute Ischemic Stroke using CT and DW-MRI

Background: Alberta Stroke Program Early Computed Tomography Score (ASPECTS) is a quantitative score to evaluate early ischemic changes in the middle cerebral arterial territory on Computed Tomography (CT) in addition to...

Download PDF file
  • EP ID EP580853
  • DOI 10.4172/2168-9784.1000266
  • Views 107
  • Downloads 0

How To Cite

Basmattie Sawh, Deivis Errada, Petal Surujpaul (2018). Assessment of Personnel Dosimetry in Radiotherapy at Cancer Institute Guyana. Journal of Medical Diagnostic Methods, 7(1), 1-4. https://europub.co.uk/articles/-A-580853