A Novelty Stability Of Electrical System Single Machine Based Runge Kutta Orde 4 Method

Abstract

In electric power systems that serve the load continuously should the voltage and frequency must remain constant, but if there is interference on one of the generators or the rail, then it is undeniable there will be disruption to the power supply. It is necessary to conduct a Research on the Stability of Power Systems relating to the Determination of Critical Breaking Angle and Critical Breaker Time on the generator, to find out how much the Critical Breaker Angle and how much of a Critical Breaker Time. In this paper used Runge Kutta Method 4th order with the help of Matlab software

Authors and Affiliations

Solly Aryza, M. Irwanto, Zulkarnain Lubis, Andysah Putera Utama Siahaan

Keywords

Related Articles

Open Access: The Multi-Licensee Tool In Emerging Indian Power Sector with Renewable Energy

The objective of this article is to analyse the role of open access electricity market with growing renewable energy penetration for energy system development and welfare in developing economy. The hypothesis is that ope...

A Novel Small-Signal Knowledge-Based Neural Network Modeling Approach for Packaged Transistors

This paper proposes a novel small-signal knowledge-based neural network modeling method for packaged transistors. Separate neural networks are proposed to represent the behaviors of packages covering the core transistor....

Comparison of Solar Photovoltaic Energy Systems Fixed Installation configuration with Single Tracking System

This paper describes the fixed PV systems tilt angle and the single tracking system. It looked at the performance of each system in terms of the voltage output and compares the two to find a better performing system. Thi...

Optimization of Energy Consumption In Electric Traction System By Using Interior Point Method

Increasing attention is being paid to optimization of energy consumption in electric traction system to reduce operational cost. Electric traction system requires electric power for propulsion of vehicles. One of the mai...

Harmonic Minimization in 31-Level Cascaded Multilevel Inverter Topology with Reduced Number of Switches

Multilevel inverters are power electronic devices that changes over DC to AC quantity. But these devices produces non-sinusoidal signal which contains harmonics. So as to be overcome this problem a 31-level cascaded mult...

Download PDF file
  • EP ID EP388226
  • DOI 10.9790/1676-1204025560.
  • Views 157
  • Downloads 0

How To Cite

Solly Aryza, M. Irwanto, Zulkarnain Lubis, Andysah Putera Utama Siahaan (2017). A Novelty Stability Of Electrical System Single Machine Based Runge Kutta Orde 4 Method. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(4), 55-60. https://europub.co.uk/articles/-A-388226