A study of preanalytical errors in a hospital based clinical biochemistry laboratory and recommendation of required corrective measures
Journal Title: International Journal of Clinical Biochemistry and Research - Year 2016, Vol 3, Issue 4
Abstract
Background & Objective: The errors associated with the total testing process in laboratory, affecting clinical decision making, may occur at the pre-analytical, analytical and post-analytical phase. This study is aimed at finding out the types and frequencies of errors recorded and recommending the corrective measures in pre analytical phase, which accounts for preventable errorssignificantly. Materials & Methods: This was a retrospective analysis of errors observed and recorded over 3 months period in clinical biochemistry laboratory at SMIMER hospital, Surat. Data analysis was done on an average of 12680 samples collected and tested. Samples included blood, urine and other fluids. Pre-analytical errors were identified and recorded subsequent to visual inspection of the samples and corresponding request forms by laboratory staff. Results: Pre-analytical errors were classified as A) inappropriate form (28.24%), B) inappropriate sample (3.52%), C) inappropriate transport (22.16%) and D) inappropriate centrifugation (7.29%). For category A, high error rate for date and time of sample collection (99.97%), provisional diagnosis (99.92%) and physician’s detail (100%) were observed. For category B, error rate for insufficient sample volume was 26.38%. For category C, error rate for date and time of sample receipt was 100%. Preanalytical error rate was highest for samples received from outpatient department (18.37%) and for urine sample (18.61%) comparatively. Conclusion: Pre-examination errors were high at this study location. Measures aimed at reducing the same and exposure to accreditation are recommended for improved laboratory quality output
Authors and Affiliations
Hasit Dalpatbhai Lad, Neeta Maheshchandra Rana, Vibhuti Sundarbhai Chaudhari, DVSS Ramavataram
Role of serum lipoprotein (a) in type 2 diabetes mellitus and its association with glycemic control
Diabetes mellitus DM is an established risk factor for cardiovascular disease At present global risk assessment lipid profile is only the blood test routinely recommended most commonly Increased lipoprotein a Lpa contrib...
Study of dyselectrolytemia in patients with multiple myeloma
Multiple myeloma MM is a malignant disease of plasma cells characterized by proliferation of a specific myelomatous clone of cells It is second most common hematologic cancer Renal impairment is observed in nearly half o...
A comparative analysis of biochemical parameters in exudative and transudative pleural fluids using different criterias: a study in a tertiary care centre
Background: Pleural effusion is a common clinical problem resulting from thoracic or systemic diseases. Several biochemical parameters, serological and cytological markers are used to classify the type of pleural effusio...
“Ratio of AST/ALT and serum gamma glutamyl transferase (GGT) activity in chronic alcoholics and acute viral hepatitis”
Background: Liver enzymes AST, ALT, GGT (Gamma Glutamyl Transferase), ALP levels in serum was measured in Chronic alcoholics and acute viral hepatitis and controls. Analysis was done to find out the significance of liver...
Evaluation of microalbuminuria in non-diabetic and non-hypertensive patients with acute myocardial infarction
Introduction: Microalbuminuria is defined as the excretion of 30to 300mg of albumin per day in urine. It is frequently present and a known cardiovascular risk indicator in diabetic populations, in hypertensive and genera...