Acceptance Tests and Quality Control of the Positron Emission Tomography (PET) Systems
Journal Title: Nuclear Medicine Seminars - Year 2020, Vol 6, Issue 2
Abstract
Quality control (QC) applications are important for the reliability and accuracy of the results obtained from positron emission tomography (PET) imaging systems in clinical trials. With these applications, exposure of patients and employees to more radiation will be prevented, and it will be possible to detect the systems that lost their performance compared to their installation time. QC applications are grouped as acceptance and reference tests, routine periodic QC tests. PET performance tests standardized by National Electrical Manufacturers Association (NEMA) should be used as acceptance and reference tests. In addition, the performance of the device should be monitored by following these tests at six-month intervals. PET/computerized tomography (CT) manufacturers often recommend routine QC procedures for their equipment and require users to follow these recommendations to a minimum. If standards are not defined for routine QC procedures, it is recommended to comply with the general minimum standards for routine QC that all PET/CT centers must perform. Routine QC protocols, the image quality of the PET system; CT image quality and CT dose of the patient; the accuracy of CT-based attenuation corrections; the accuracy of the CT and PET co-registration should ensure that problems that can interact any of the performance characteristics are identified. Since performing PET/CT scans by equipment that does not comply with their specifications may compromise image quality, interpretation of images and reliability of results, daily QC parameters must be evaluated and necessary corrective procedures must be taken prior to scanning. The tests are carried out using the protocol provided by the manufacturer.
Authors and Affiliations
Tuğba Hacıosmanoğlu, Mustafa Demir, Türkay Toklu, F. Suna Kıraç, Mehmet İnce, Yasemin Parlak, Bilal Kovan, Semra Dönmez, Aslı Ayan, İnci Alıç Özaslan, Meral Hiçürkmez, Nami Yeyin, Leyla Poyraz ve TNTD Kalite kontrol ve Radyasyon Güvenliği çalışma grubu üyeleri
Standardized Reporting of Myocardial Perfusion SPECT Imaging
Myocardial perfusion single photon emission computerized tomography (MPS) report is the final product of a series of complex procedures, starting with patient preparation and ending with interpretation of the process. Th...
Procedur Guideline for Lymphoscintigraphy and Sentinel Lymph Node in Breast Cancer
Sentinel lymph node (SLN) detection by lymphoscintigraphy (LS) and using intraoperative gamma probe is the mostly important prognostic factor in patients with breast cancer. Sentinel lymph node biopsy (SLNB) is a procedu...
The Role of Thyroglobulin in the Management of Thyroid Cancers
Thyroglobulin (Tg), a glycoprotein that is synthesized in normal thyroid, is a significant biochemical marker of residual thyroid tissue or recurrent/metastatic disease in differentiated thyroid cancers (DTC). In this ma...
F-18 FDG PET/CT Practice Guideline in Oncology
Positron emission tomography (PET) is a tomographic imaging method that shows three-dimensional distribution of radiopharmaceuticals which are labelled with positron emitter radionuclides. Today most widely used PET radi...
Treatment Methods for Pain due to Bone Metastases
Bone metastases are the most common cause of cancer pain, and up to two-thirds of patients with bone metastases will suffer severe pain. Given the complexity of the treatment decisions, multidisciplinary evaluation is us...