Analysis of Current Harmonics in 3kV DC Catenary Caused by Specific Current Harmonics of an Asynchronous Motor

Journal Title: Archives of Transport - Year 2010, Vol 22, Issue 3

Abstract

The mathematical model of vehicle supply system as well as the mathematical model of main circuit of locomotive with asynchronous motors have been described in this article. The necessity of analysis of disturbances caused by distorted current run of drive motors emerged together with the introduction of high power vehicles with power electronic converters. Analysis of the compatibility of traction high current circuits with circuits of the signal and traffic control systems requires the knowledge of current spectrum in a catenary, which has been taken by a vehicle. The author has described the algebraic method of calculating of the spectrum amplitudes in a catenary. It does not require laborious and time-consuming simulations of a system, which considerably decreases preliminary costs of designation and dimensioning of a vehicle drive system.

Authors and Affiliations

Mirosław Lewandowski

Keywords

Related Articles

aaaaaaa

dsadsadsa dsdasadsad

Regional implementation of a road safety observatory in Poland

The paper outlines the background and goals of the Road Safety Observatory in the Polish region of Warmia and Mazury. While created it was Poland’s first road safety Observatory, both at the regional and central level. E...

Designing and efficiency of database for simulation of processes in systems. Case study for the simulation of warehouse processes

The basis of each IT system is data exchange both between individual modules of program and between program and user. The number of exchanged data and the number of operations on the data, which should be performed, requ...

Safety factor in the sustainable fleet management model

In the era of rapidly changing market and consumer needs, there are dynamic changes in the services offered. This also applies to the car fleet market. Currently, the approach to owning a vehicle is changing to other for...

Proposed benchmarks for PRT networks simulation

Personal Rapid Transit (PRT) is a promising form of urban transport. Its operation relies on the use of small unmanned vehicles which carry the passengers between the stations within a dedicated network. Various aspects...

Download PDF file
  • EP ID EP70207
  • DOI 10.2478/v10174-010-0017-y
  • Views 113
  • Downloads 0

How To Cite

Mirosław Lewandowski (2010). Analysis of Current Harmonics in 3kV DC Catenary Caused by Specific Current Harmonics of an Asynchronous Motor. Archives of Transport, 22(3), 289-301. https://europub.co.uk/articles/-A-70207