Analysis of efficiency of multi section linear induction-dynamic accelerator with outer shield
Journal Title: Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика - Year 2015, Vol 42, Issue 1151
Abstract
Developed the computer model of multi section linear induction-dynamic accelerator (LIDA) massive actuator, which takes into account the interconnected electromagnetic, mechanical and thermal processes. Synthesized the parameters of multi section LIDA for maximum efficiency with minimum magnetic leakage fields. Performed the analysis of multi section in the absence of the screen with the use of a ferromagnetic (FE) and the combined screen. The lowest speed provided LIDA without a screen, and the highest - when using FE. In LIDA without screen the level leakage fields is 1.6 times lower than in a single section accelerator with FE. In the presence of FE level leakage fields in LIDA reduced by 2.3 times, and in the presence of the combined screen – 7.2 times.
Authors and Affiliations
V. F. Bolyukh, S. V. Oleksenko
Modified robust ridge estimates to determine outliers
Least squares estimates (LSE), in a multiple linear regression when the predictors are strongly correlated, give low prediction accuracy. Ridge regression, being regularized version of the regression based on least squar...
Automation of control by feed-pumps of a 200 MW power unit
A review and analysis of control systems and relay protection of feed-pumps and technical requirements of them are carried out. Possibility of replacement of the relay control system is reasonable to the automatic system...
Power transformer station 330/110 kV power lines in the presence of harmonics
Disabling or damage to overhead power lines of high and extra-high voltage (power lines) caused by various reasons, among which is not the last place is occupied by both natural factors - the effects of lightning and bir...
Bot protection surge in power in the presence of higher harmonics
Overvoltage suppressors are protection devices used at high-voltage substations. These apparatus are main substation equipment protection against overvoltage. Overvoltage suppressor breakdown results in heavy accidents w...