Features reversible thyristor contactless synchronous rectifier machines depending on the control angle
Journal Title: Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика - Year 2015, Vol 42, Issue 1151
Abstract
Techniques for calculating the characteristics of reversible thyristor rectifier for contactless synchronous machines, depending on the angle of thyristor control, are presented. Calculation of the protective circuits of thyristor rectifier is held at a zero control angle following the method of calculation of diode rectifiers. Changing thyristor control angle from 0 to 90 degree does not increase the maximum stress voltage on the thyristor. Calculation models of thyristor rectifier is conducted in the circuit simulation in a quasi-steady or transient operating conditions. The calculation models rectifier in transient modes of operation are limited to the number of variables, the current numerical values are recorded in the memory of the program, the calculation is performed at a frequency thyristor control the lower frequency power supply rectifier. The results of calculation models rectifier diode and transistor should be used in the comparative analysis of contactless synchronous machines exiters.
Authors and Affiliations
А. М. Galynovskiy, E. А. Lenskaya
Improving the reliability of protection of household electric networks by using complex criteria of actuation protective devices
The necessity and possibility of increasing the reliability of protection of household electrical networks due to the transition to comprehensive criteria of tripping formed from a combination of several parameters of th...
Regularities of electromagnetic processes in the contactless excitation system of an asynchronous generator following a two-star scheme based on a threephase-threephase voltage modulator
By means of mathematical modeling there have been studied regularities of electromagnetic processes taking place in the contactless excitation system of an asynchronous generator based on cascade, three-phase-three-phas...
Bot protection surge in power in the presence of higher harmonics
Overvoltage suppressors are protection devices used at high-voltage substations. These apparatus are main substation equipment protection against overvoltage. Overvoltage suppressor breakdown results in heavy accidents w...
Parameters and characteristics of low power generators for wind power plants on the basis of asynchronous motors with a short circuited rotor
The technical literature provides conflicting recommendations on the use of asynchronous machines with a short-circuited rotor of industrial production in wind power plants of low power when operating in parallel with th...
The analysis of datas of temperature calculation of high-voltage cables with cross-linked polyethylene insulation
World tendecies in the development of high voltage energy distribution systems for the last decades have been focused on implementing of cables with heat-resistant extruded insulation. This cables have a range of advanta...