The analysis of datas of temperature calculation of high-voltage cables with cross-linked polyethylene insulation
Journal Title: Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика - Year 2014, Vol 41, Issue 1084
Abstract
World tendecies in the development of high voltage energy distribution systems for the last decades have been focused on implementing of cables with heat-resistant extruded insulation. This cables have a range of advantage consist of increased operating temperature of 90 °C. The analysis of datas of temperature calculation on power cables with cross-linked polyethylene (XLPE) insulation at for rated voltage of 64/ 110 kV AC. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables. The temperature of insulation are calculated for the following conditions: conductor temperature 90 °C; ambient temperature 15 °C at in air.
Authors and Affiliations
L. А. Scebenjuk, Т. J. Аntonec
A technique for induction cookers’ inductors calculation
In the paper a technique for the calculation of inductor – main structural part of an induction cooker is proposed. The presented technique is developed on the base of engineering methods for calculation of industrial in...
Analysis of ways to modernize the traction motor DC DTН-45/27 for the drive of miner contact electric locomotive
Purpose. A comparative analysis of parameters and designs DC traction motors to identify technical solutions aimed at improving the technical and economic indicators. Methodology. On the basis of the comparative analysis...
Research of the induction-dynamic mechanism operation characteristics
The design of the linear-drive induction-dynamic mechanism used in high-speed breakers is presented. The research mechanism consists of a coil with leads and a moving disk. The coil of the mechanism is wound with copper...
A technique for structural analysis of subsystems of utilities for power supply systems of technical means for frontiers protection
A technique for determining the set of rational structures of subsystems of utili-ties for power supply systems of technical means for frontiers protection on the base of renewable energy potential is proposed. It is sub...
Influence of number of radial slits of ferromagnetic screen on linear induction-dynamic transducer attributes
Proposed the concept of a linear induction-dynamic transducer (LIDT) in which ferromagnetic screen (FS) is provided with radial slits. It was found that an increase in the number of radial slits decreases the induced cur...