Determination of frequency-controlled induction motor rotor’s equivalent thermal circuit thermal resistance
Journal Title: Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика - Year 2015, Vol 42, Issue 1151
Abstract
The necessity of frequency-controlled induction motor study thermal state is determined by frequent failure of these motors due to overheating of the stator windings, especially in non-stationary modes. The determining method of frequency-controlled induction motor rotor’s winding thermal resistance, which are part of the frequency-controlled induction motor equivalent thermal circuit dynamic parameters are detailed considered in the paper. The mathematical model obtained based on the given thermal equivalent circuit used for the frequency-controlled induction motor thermal state research. The efficiency and adequacy of the obtained frequency-controlled induction motor thermal state mathematical model are experimentally confirmed. The research results in previously published papers are detail considered [1-6].The paper material complements these papers and makes it easier for induction motor design professionals to study and use the given method.
Authors and Affiliations
A. N. Petrenko, V. P. Shajda, N. Ya. Petrenko
Power transformer station 330/110 kV power lines in the presence of harmonics
Disabling or damage to overhead power lines of high and extra-high voltage (power lines) caused by various reasons, among which is not the last place is occupied by both natural factors - the effects of lightning and bir...
Development latch short-circuit for overhead power line voltage of 110 - 150 kV
Proposed a simple design of electromechanical latch short-circuit for overhead power line voltage of 110-150 kV. For the selected constructions shows a method of calculating its technical characteristics. Experimentally...
Development and implementation indicator power consumption in the electrical distribution network
The question of the implementation of effective controls electrical parameters of three-phase networks and major consumers of electricity. It is proposed to develop energy indicator parameters for three-phase ac circuits...
Detection of burnout of tubular electric heaters, included in the three-phase network with the star scheme with the neutral on change of current of neutral with the help of current relay
Was offered a determination of the failure connected with wires’ burnout or burnout of spirals of tubular electric heaters with identical power included in a three-phase network according to the star scheme with a neutra...
The choice of a rational number of sources of power system load mutual traction electrical machines
Problems of selection of rational variants of traction electric machines mutual loading schemes to carry out their acceptance test are considered. It is substantiated that discrepancy of magnetic characteristics of tract...