ANALYSIS OF INFLUENCE OF INTERNAL CONVERTERS NONLINEARITY ON INTELLIGENT CYCLIC ADC PERFORMANCE

Journal Title: Metrology and Measurement Systems - Year 2005, Vol 12, Issue 4

Abstract

The task of the paper is the presentation of a modelling approach to quantitative analysis of the influence of internal converter nonlinearities on the performance of sub-optimal intelligent cyclic A/D converters (IC ADCs) developed and analysed in works [1-5] and others. The results of investigations permit to determine requirements to the analogue elements of IC ADC architecture, first of all to an internal low-bit A/D converter (ADCIn), which is the most crucial for the design and practical implementation of IC ADC.

Authors and Affiliations

KONRAD JĘDRZEJEWSKI, ANATOLIY PLATONOV

Keywords

Related Articles

COMPARISON BETWEEN SIMPLE POLYNOMIALS AND AN ITS-90 BASED REFERENCE FUNCTIONS OF EMF VS. TEMPERATURE RELATION FOR HIGH PURITY NOBLE METAL THERMOCOUPLES

Emf versus temperature reference polynomial functions covering the temperature range from 100° C up to 960° C have been developed for three types of noble metal thermocouples, which are Pt-10%Rh/Pt, Au/Pt and Pt/Pd. Our...

PERFORMANCE ASSESSMENT OF "FIELD PROGRAMMABLE ANALOG ARRAYS"

Field Programmable Analog Arrays (FPAAs) are reconfigurable analog modules introduced on the electronic market in the last decade. Their operation and, in particular, their programmability is achieved owing to the use of...

RESEARCH ON HYSTERESIS OF TRIGGERING PROBES APPLIED IN COORDINATE MEASURING MACHINES

The article presents selected results of investigation of triggering probe hysteresis in coordinate measuring machines. The research covered the hysteresis of pretravel of one-stage triggering probes equipped with a swit...

IMAGE PROCESSING SYSTEM PROPOSED TO BE APPLIED IN A GASTROSCOPIC LABORATORY

The article presents a way to integrate an endoscope with computer equipment. Software has been proposed to archive and access results of endoscopic tests. The data can be accessed at the hospital area and from outside i...

COMPARISON OF CAPACITORS BY MEANS OF A DOUBLE-CHANNEL DIGITIZER

In the paper, a comparative method of measurement of the capacitors by measuring the voltages across them and phase angle between is presented. In the analysis of errors the systematic loading effects of the connection a...

Download PDF file
  • EP ID EP134145
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

KONRAD JĘDRZEJEWSKI, ANATOLIY PLATONOV (2005). ANALYSIS OF INFLUENCE OF INTERNAL CONVERTERS NONLINEARITY ON INTELLIGENT CYCLIC ADC PERFORMANCE. Metrology and Measurement Systems, 12(4), 343-354. https://europub.co.uk/articles/-A-134145