Analysis of Power Transfer Capability of a Long Transmission Line Using FACTS Devices

Abstract

power transfer capability by analyzing and comparing several FACTS devices such as Static Var Compensator (SVC), Static Synchronous Compensator (STATCOM) and Unified Power Flow Controller (UPFC) in long transmission line. These devices have been used in different locations such as sending end, middle and receiving end of transmission line. The suitable location and performance of each model has been analyzed. Firstly, real and reactive power profiles have been studied for uncompensated system and subsequent results are produced. Then these results are compared with the results obtained after compensating the system using afore mentioned FACTS devices. Overall analysis indicates that better power (i.e. 87.24% power) has been transferred when SVC is connected at the middle of the transmission line. All simulations have been done in MATLAB/SIMULINK. K. Suneel Goutham | M. Bhaskar Rao | T. Jaganmohan Rao"Analysis of Power Transfer Capability of a Long Transmission Line Using FACTS Devices" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-4 , June 2018, URL: http://www.ijtsrd.com/papers/ijtsrd15615.pdf http://www.ijtsrd.com/engineering/electrical-engineering/15615/analysis-of-power-transfer-capability-of-a-long-transmission--line-using-facts-devices/k-suneel-goutham

Authors and Affiliations

Keywords

Related Articles

Biosorption studies of lead II from aqueous solution by immobilized Sugarcane bagasse Saccharum officinarum L. onto alginate Polvinyl glutaraldehyde

The effectiveness of low-cost biosorbent immobilized Sugarcane bagasse Saccharum officinarum L. onto alginate Polvinyl glutaraldehyde, was studied for Lead II biosorption from aqueous solutions in a batch system. The FTI...

Enhancing Cloud Security by Analyzing Venerability of Cloud Server in D-Dos Attack

Now a day's more and more services and applications are emerging in the Internet, exposing sensitive electronic data in the internet has become easier. Web services cause's personal data to be cached, copied, and archive...

Preparation and Biological Screening of Novel Heterocyclic Compounds

The Pyrimidone derivatives say, N arylidine 6 methyl 2 oxo 4 phenyl 1,2,3, 4 tetrahydropyrimidonecarbohydrazides 2a e were synthesized by condensation of Benzaldehyde derivatives with 6 Methyl 2 oxo 4 phenyl 1,2,3,4 tetr...

Waste Management System by Using IoT

Solid waste management is one of the major aspect which has to be considered in terms of making urban area environment healthier. The common dustbins placed by the municipal corporation are leading number of health, envi...

Deep Learning in Medicine

Spurred by advances in processing power, memory, storage, and an unprecedented wealth of data, computers are being asked to tackle increasingly complex learning tasks, often with astonishing success. Computers have now m...

Download PDF file
  • EP ID EP362162
  • DOI -
  • Views 90
  • Downloads 0

How To Cite

(2018). Analysis of Power Transfer Capability of a Long Transmission Line Using FACTS Devices. International Journal of Trend in Scientific Research and Development, 2(4), -. https://europub.co.uk/articles/-A-362162