Analysis of the microwave self-noise influencing on the parameters of the Dicke radiometer
Journal Title: Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування - Year 2012, Vol 0, Issue 51
Abstract
Introduction. The application domains of the radiometric measuring are described and the basic types of radiometers are listed. The best "price – measurement precision" index (in the authors' opinion ) has a Dicke radiometer. The microwave self-noise level of this radiometer very affects on the measurement precision. It is a function of the waveguide devices characteristics, generally, of the microwave switch parameters. Microwave noise sources of the radiometer. A mixer and heterodyne are the basic sources of microwave noises in a radiometer. Analysis of the self-noise influence on the measurement precision of the radiometer with pin-modulator in the switching mode. The considered radiometer involves a pin-diodes switch. The theoretical and experimental investigations show, that the level of microwave noise depends on the channels nonidentity of the switch, and also on mismatch of its ports. Abatement of noise is possible due to reduction of the heterodyne noise factor of the radiometer, antennas noise, and also reduction of the input and output switch mismatch factors. Analysis of the self-noise influencing on the measurement precision of the radiometer with pin-modulator in the commutation mode. The results of experimental determination of the basic radiometer characteristics in this mode are described. The main devices of the radiometer waveguide transmission line are analyzed. Their influence on the input power measurement precision is shown. The computation data of the measurement error are cited for the concrete parameters of the microwave devices. In the event that a relation a "signal – noise" equals 1 and the switch coefficient of reflection is 0,35-0,55, the error can equal 18%. It is suggested to decrease considerably this error through an additional ferrite isolator and using the switches with similar waveguide channels. Conclusion. Comparison of the offered methods shows that adding ferrite isolator and using the switch with similar waveguide channels are preferential. That allows ignoring the microwave self-nose influence on the measurement precision.
Authors and Affiliations
A. Yanenko, S. Peregudov
Phase measuring device based on coincidence method
Introduction. The aim of the study was to determine perceptivity usage of the coincidence method for the implementation of phase measuring device. It was necessary to establish the structural elements of the measuring de...
The comparative analysis of the basic standards of video for transmition on 4G-networks
In this article review and the analysis of the basic standards of video which can be used for transmission of the multimedia information on 4G-networks are executed; also comparison of key parameters which influence on e...
Calculation of radio energy of Wi-fi signal in the railway coach
Introduction. Access to the Internet through mobile networks 3G, compared with other systems, has considerably lower cost of the implementation, and the best speed characteristics that makes its use more efficient. Moder...
Electrostatic model applicators for hypothermia
The structural feature of applicators is examined for hyperthermia that possibility of calculation of the electromagnetic fields and division of temperature in біотканинах at treatment of hyperplasia of peredmikhurovoy g...
Comparison of circuit optimization time for different strategies of structural basis
The design methodology for analog circuits developed earlier on the basis of using the control theory makes it possible to apply important concepts and results of the specified theory. Lyapunov function defined for the e...